GENERAL

The Eemax “Three Phase Thermostatic DI” water heater is specifically designed to take in
cold or pre-heated De-ionized water and heat it to temperatures suitable for commercial
washing, sluicing or processing up to a maximum temperature of 180 F (82 deg. C). To 
obtain optimum performance and energy savings, the unit should be located as near as
possible to the point of use. The unit must only be installed in a vertical position with the inlet
and outlet at the bottom. The power is activated by individual electronic flow switches located
in each of the three heating modules. These will be damaged by excessive heat, do not solder
any pipes that are in contact with the heater.
Also ensure pipes are clear of installation debris before fitting the heater, otherwise the flow 
switches could jam in the “on” position. The unit must be connected to its own individual electric 
circuit protected by a suitably rated four pole breaker. The maximum voltage which can be
applied across any heating module is 277 volts. 

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause DEATH,
SERIOUS BODILY INJURY OR PROPERTY DAMAGE. Refer to this manual for
assistance or consult the local electric utility for further information.

The unit is supplied with compression pipe fittings suitable for direct coupling to standard
1/2 “ piping. There is no need for additional screwed fittings.

WARNING

Failure to ground the system may result in death or serious injury. 

2

Summary of Contents for EX180TDI

Page 1: ... EX320TDI EX240TDI EX180TDI 480 277 Volts only INSTALLATION GUIDE AND OWNERS MANUAL E X ema TM PLEASE TAKE THE TIME TO READ NOT ONLY THIS MANUAL BUT ALSO THE WARRANTY CARD ENCLOSED WARRANTY OF THIS WATER HEATER WILL DEPEND ON CORRECT INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN OR STRUCTURE OF THE WATER HEATER HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS W...

Page 2: ...any pipes that are in contact with the heater Also ensure pipes are clear of installation debris before fitting the heater otherwise the flow switches could jam in the on position The unit must be connected to its own individual electric circuit protected by a suitably rated four pole breaker The maximum voltage which can be applied across any heating module is 277 volts WARNING Improper installat...

Page 3: ... the unit for easy replacement of the elements 5 The heater should be fixed to the wall using screws in the four mounting holes at each corner of the backplate 6 The unit should be installed in the plumbing system in such a way that there is no tendency for the unit to be starved of water for example by an excessive draw off of cold water just before the unit Also do not fit an unrestricted hot wa...

Page 4: ... isolating valves full flow ball valve type on both inlet and outlet pipes This allows unit to be isolated for maintenance purposes see Fig 1 4 When all plumbing is complete fully check the system for water leaks at all plumbing connections If leak is present take corrective action Fully open both inlet and outlet ball valves Run all hot water outlets fed by this heater one at a time for a minute ...

Page 5: ...ive neutral and one ground of the appropriate rating protected by the correctly rated three pole breaker DANGER FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY IMPORTANT BEFORE SWITCHING ON THE POWER AT THE MAIN CIRCUIT BREAKER PANEL MAKE SURE THAT THE HOT WATER CIRCUIT IS FREE OF AIR POCKETS OR PREMATURE FAILURE OF THE ELEMENT WILL OCCUR TO DO THIS OPEN ALL HOT WATER OUTLETS ON...

Page 6: ...nt water temperature may not be hot 5 Using the OUTLET BALL VALVE slowly reduce water flow until desired temperature is achieved at hot water outlet NOTE The water temperature is regulated by the flow through the heater The lower the flow the higher the temperature and vice versa MINIMUM SETTING MAXIMUM SETTING THE TEMPERATURE CONTROLLING POTENTIOMETER IS A PRECISION COMPONENT ADJUST GENTLY AND DO...

Page 7: ...BE ON WHEN WATER IS FLOWING THROUGH THE UNIT For expected temperature rise at various rates of flow see chart 8 It is possible that drawing off cold water at comparatively high rates of flow elsewhere in the building at the same time that the heater is working could cause premature element failure Care should be taken not to starve the unit of cold water To prevent this from happening open fully t...

Page 8: ...ont cover of this manual for the correct value If the resistance is much greater than the correct value call your supplier for a replacement element SYMPTOM NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON 1 WATER FLOW TOO HIGH Reduce the water flow by using an outlet ball valve See page 5 for temperature rise at various flow rates 2 INCORRECT POWER SUPPLY Make sure that the unit is connected to...

Page 9: ...UST BE GROUNDED This heater is only suitable for 4 wire 3 phase connection with a maximum of 277 volts across each element REPLACEMENT PARTS DIAGRAM THERMOSTATIC PCB PART EX100 DI HEATER CORE ASSEMBLY FOR EX180 T3 DI PART EX1280 DI FOR EX240 T3 DI PART EX960 DI FOR EX320 T3 DI PART EX720 DI TRIAC PART EX18 9 ...

Reviews: