Operating instructions
10
⇒
Fill the fresh oil in at the spout.
⇒
Dispose of the used oil in an environmentally
responsible manner.
Oil drain plug Oil filler cap
AIR SUCTION FILTER
CONTROL INTERVALS
State of soiled
suction air
heavy moderat
e
light
Control
daily
weekly
every
500
hours
Depending on the type, your unit is fitted
accordingly with one or other of the following air
filters:
A.)
B.)
CHECKING THE DRIVE BELT
After every 500 operating hours, check the
condition and tension of the drive belt. If there are
any cracks in it, or if it looks brittle, replace it.
Tighten up the tension on it if it is too slack.
PRESSURE SWITCH
Operating instructions for the pressure switch are
enclosed with it. Note the maximum values when
adjusting the pressure switch.
CYLINDER HEAD SEAL
After the first 100 operating hours, the bolts on the
cylinder head seal must be tightened.
TORQUE WRENCH SETTINGS
Bolt Maximum
torque
M 8
25 Nm
M 10
50 Nm
M 12
85 Nm