Operating instructions 

 
 

11

 

RECTIFYING MALFUNCTIONS 

Malfunction

 

Cause

 

Remedy

 

 

Oil level rises 

 

Drops of water in oil 

 

Oil has milky colour 

Water has collected in the crank 
housing. Operating temperature is 
not being reached because the 
switch-on times are too short. 

Change oil at once 
Use a smaller compressor if 
necessary 

 

Water has collected in the crank 
housing because the machine is 
installed in a damp place. 

Change oil at once 
Select a dry place for installation  

 

Motor cut-out has been triggered 

Ambient temperature is too high 

Ventilate the room or choose a 
cooler place for installation 

 

Supply voltage is wrong 

Ask a qualified electrician to check 
supply voltage and cross-sections of 
the supply wiring. 

 

Valves are defective 

Replace the valves 
Recommendation: call in EFA 
Service-Department 

 

Low air delivery 

Suction filter clogged 

Clean / replace suction filter 

 

Excessive oil consumption 

Wrong oil is being used 

Check the type of oil 

 

Wear between the piston-rings and 
the cylinder walls 

Replace the piston rings 
Recommendation: call in EFA 
Service-Department 

 

Air is escaping through the safety 
valve on the storage tank 

Pressure switch is set too high 

Check the pressure switch settings  

 

Air is escaping from the 
depressurisation pipe on the 
pressure switch or the solenoid 
valve 

Non return valve is defective 

Check the non return valve 
Recommendation: call in EFA 
Service-Department 

 

Air is escaping from the 
depressurisation pipe of the 
pressure switch or the solenoid 
valve whilst compressor is 
running. 

Air relief valve or pressure switch 
dirty or defect 

Check air relief valve 
Recommendation Call in EFA 
Service Department 

 

Automatic condensate drain 
(option) lets out water constantly 

Automatic condensate drain is 
polluted 

Clean condensate drain (this can not 
be claimed unter quaranty) 

 

MAINTENANCE – OVERALL VIEW 

 

After 100 working 
hours, max. 6-8 weeks 
after inital start 

After 500 working 
hours, at least once a 
year 

After 2000 working 
hours, at least every 2 
years 

Change Oil 

 

 

 

 

 

 

Check air filter for pollution 

 

 

 

 

 

 

Regulate tension of the V-belt 

 

 

 

 

 

 

Clean automatic condensate drain 
(option) on air receiver 

 

 

 

 

 

 

Check valve for erosion 

 

 

 

 

 

 The given intervals are based on experience. They can differ considerably depending on the 

operating conditions. 

 Always tighten all screw connections that have been loosened during maintenance work. 

 

Summary of Contents for 001 606 885

Page 1: ...Betriebsanleitung 2 Operation manual VB 125 235 Type VB 125 to 235 PISTON COMPRESSORS...

Page 2: ...triebsanleitung 3 2 6 3 8 4 9 5 10 EFA 001 606 885 001 606 886 230 400 50 230 50 7 2 4 4 A 11 0 A F F 1800 1800 1400 1400 2 2 2 2 160 160 15 15 6 6 IP54 IP54 76 A 76 A 25 25 x x 550x470x420 550x470x42...

Page 3: ...Betriebsanleitung 4 EFA 6 EFA...

Page 4: ...Betriebsanleitung 5...

Page 5: ...Betriebsanleitung 6 40 5 C 40 C 10 10 3...

Page 6: ...Betriebsanleitung 7 0 0 1...

Page 7: ...Betriebsanleitung 8 0 15 20...

Page 8: ...BP Energol RC 150 BP Energol RC 100 BP Energol HD S SAE 20 W 20 BP Energol RC S100 Shell Corena l H150D Shell Corena l H100D Shell Rotella X 20 W 20 V l 7010 3022 N 3021 N Essolube HDX Plus 30 Mobil R...

Page 9: ...Betriebsanleitung 10 500 100 M 8 25 M 10 50 M 12 85...

Page 10: ...Operating instructions 2 EFA EFA Service anfordern EFA EFA Service anfordern EFA EFA Service anfordern EFA 100 6 8 500 2000...

Page 11: ...8 servicing unit 4 pressure switch 9 compressor aggregate 5 condensate drain 10 air receiver Order no EFA 001 606 885 001 606 886 voltage Frequency 230 400V 50Hz 230V 50 Hz current 7 2 4 4 A 11 0 A I...

Page 12: ...Stufig 2 Stufig cylinder 2 2 suction capacity 160 l min 160 l min max pressure 15 bar 15 bar tank capacity 6 l 6 l Protection IP54 IP54 sound level 76 dzB A 76 dzB A weight 25 kg 25 kg dimension LxBx...

Page 13: ...takes inadequate maintenance incorrect consumable material installation of the wrong replacement parts please only ever use original EFA parts improper technical alterations to the machine failure to...

Page 14: ...to the ground and could cause very serious injury It is strictly forbidden to move or stand in the danger area underneath a suspended load CAUTION Improper lifting Lifting the compressor in the wrong...

Page 15: ...n continues to run for a short time until the machine has cooled down INSTRUCTIONS FOR ELECTRICAL CONNECTION The electrical connection and safety precautions must comply with VDE regulations and or ot...

Page 16: ...let the air off automatically so as to ensure that the compressor can start up again with no load against it Pressure in the storage tank will be maintained Turn the lockable master switch off or plu...

Page 17: ...temperature This condensation then reduces the lubricating effect on pistons and bearings and that could destroy them completely The signs of condensation in the lubricating oil are an excessively hig...

Page 18: ...ing air filters A B CHECKING THE DRIVE BELT After every 500 operating hours check the condition and tension of the drive belt If there are any cracks in it or if it looks brittle replace it Tighten up...

Page 19: ...nt Air is escaping through the safety valve on the storage tank Pressure switch is set too high Check the pressure switch settings Air is escaping from the depressurisation pipe on the pressure switch...

Page 20: ...n class F F Power 1800 1800W Rotation 1400 1400 U min Build 2 two stage Cylinder 2 2 Suction capacity 160 160 l min Max pressure 15 15 bar Tank capacity 6 6 l Protection P54 P54 Sound level 76 dB A 76...

Page 21: ...4 2 Gasket 5 2 Valve plate 6 2 Gasket 7 2 Gasket 8 1 Cylinder 42 9 1 Cylinder 55 10 4 Nut M8 UNI 5587 11 4 Stud Bolt 12 1 Con rod 13 1 Piston 42 14 1 Piston rings 15 2 Ring 16 2 Piston pin 17 1 Oil le...

Page 22: ...4 1 Fan 45 1 Washer 46 1 Washer 47 1 Screw M8x20 48 3 Screw 4 2x12 7 49 1 Rear protection 50 1 Three phase cover 51 2 Screw 3 9x12 7 52 1 Stretch eliminator 53 1 Thermal protection 100 2 Set of gasket...

Page 23: ...Schmid Wezel D 75433 Maulbronn Page 13 15 Version 09 2008 A 4...

Page 24: ...Schmid Wezel D 75433 Maulbronn Page 14 15 Version 09 2008 A 5 Installation plan 200 2000...

Reviews: