8. Maintenance 

Malfunctions  may  occur  during  operation,  but 
these  are  generally  relatively  simple  to 
remedy.  

 

ATTENTION 

Only  qualified,  instructed  specialist 
personnel 

may 

carry 

out 

all 

operations. 

 

Table  1:  "Faults  and  corrective  measures" 

describes  these  malfunctions  together  with 
their  possible  causes  and  suggests  corrective 
measures 

The machine does not start up when 
actuating the switch lever 

Air filter on maintenance unit is dirty 

Replace air filter 

Loose hose connection 

Check the proper connection of the 
hoses 

Rotor slide defective 

Return to manufacturer for service. 

Handle is difficult or impossible to 
press 

Valve spring broken 

Valve jammed due to soiling 

Return to manufacturer for service. 

Handle iced 

Air pressure set too high 

Adjust to 6 - 8 bar 

Machine does not start 

Parts of the motor or transmission are 
defective 

Return to manufacturer for service. 

Machine parts corroded 

Water in inlet line. Air conditioner 
defective 

If necessary, replace maintenance unit 
or return to manufacturer for service. 

Tab 1  Malfunctions and their rectification 

 

8.1.1 

Repair by After-Sales Service 

Only  specialized  persons  are  authorized  to 
perform  repairs.  Our  service  department  is  at 
your disposal for any repairs needed.  

If your equipment needs to be repaired, please 
contact  the  nearest  authorized  service  center 
or our head office. 

Upon  request,  spare  parts  lists  can  be 
provided to any authorized service center. 

In  the  event  of  malfunctions  that  cannot  be 
clearly localized, the device should be returned 
to  S&W  for  repair.  Please  state  the  error 
symptoms if you do so. 

For  other  faults  that  the  system  operator  can 
rectify,  the  fault  list  may  provide  information 
about the cause and rectification of the fault. 

 

Do  not  repair  defective  devices  on 
site  (in  the  immediate  vicinity  of 
food)! 

Provide  all  of  the  necessary  tools 
and 

ensure 

that 

the 

work 

environment is clean. 

 

 

WARNING 

Cutting hazard! 

Disconnect  the  device  from  the 
compressed 

air 

supply 

before 

starting any repairs!  

 

 

WARNING 

Cutting hazard! 

Turn  off  and  disconnect  the  saw 
from  the  compressed  air  supply 
before starting maintenance!  

 

 

CAUTION 

Malfunction 

Possible cause 

Remedy 

Summary of Contents for 16-8D

Page 1: ...A 17 EFA 19 EFA SK 08D EFA SK 16D EFA SK 16 8D EFA SK 16 8DR EFA SK 18 8D This manual must be given to the user worker A copy of this manual must be given to all personnel working with this tool Schmi...

Page 2: ...splatz 7 4 2 Installation 7 4 2 1 Druckluft Kreiss ge anschlie en 7 4 2 2 Filterdruckminderer 8 4 2 3 Federzug 8 5 Handhabung 9 5 1 Schalterbet tigung 9 5 1 1 Einschalten 9 5 1 2 Ausschalten 10 5 2 Ar...

Page 3: ...ung 15 7 2 1 Werkzeuge und Zubeh r 15 7 2 2 Schmierung 15 7 2 3 S geblatt 15 7 3 Erweiterte Wartung 15 7 3 1 Wartung der S ge 15 7 3 2 Sch rfen des S geblattes 16 7 3 3 Wartungseinheit 16 8 Instandhal...

Page 4: ...WARNING Death severe injury or significant property damage may occur if proper precautions are not taken CAUTION Minor Injury may occur if proper precautions are not taken Mandatory sign Danger to ind...

Page 5: ...effect on the active and passive safety Schmid Wezel GmbH accepts no liability for damage caused using non original spare parts or special designs Modifications and alterations to the machine are not...

Page 6: ...vices disconnected from compressed air supply Read the operating instructions carefully comply with the instructions therein and store them in a place where they are accessible to everyone at all time...

Page 7: ...cessories will void the warranty The use of other tool inserts or accessories presents a risk of injury to you and other persons Lay down the unused pneumatic circular saw so that accidental contact w...

Page 8: ...has accumulated moisture Therefore a filter pressure reducer with water separator should be installed between the compressed air system and the tool This not only controls the operating pressure but c...

Page 9: ...Cutting hazard Limbs may be severed Never reach into the area of the saw blade Wear eye protection or safety goggles during work The pneumatic circular saw is equipped with a valve lever 1 for connect...

Page 10: ...ve application Adjust cutting depth with stop if present loosen wing nut 2 and swivel stop 1 over pivot point 3 Tighten the wing nut 2 see Abb 6 Adjustment range 15 65 mm Adjusting the cutting depth S...

Page 11: ...e needed for disassembly assembly Single open end wrench accessory Retention pin 6 1 1 Removing the depth stop EFA 17 SK16D SK16 8D 1 Loosen the screw 1 at the pivot point 2 Unscrew the wing nut 2 and...

Page 12: ...d to be detached from the saw blade Do not remove the sealing washer 7 with the saw blade 3 EFA SK 08D 1 Insert retaining pin 1 into hole 2 2 Hold drive arm 3 with retaining pin 3 Loosen nut 4 with si...

Page 13: ...asher 2 2 Slide the upper spring washer 3 over the drive arm 4 onto the saw blade 3 Secure the drive arm with the retaining pin 5 and tighten the nut 6 with the single open end wrench 7 6 2 Adjusting...

Page 14: ...ly clean The machine should normally be disinfected before each cleaning Observe the applicable safety and hygiene requirements 7 1 1 Disinfection Disinfect the machine during operation after every cu...

Page 15: ...e from the sales department of Schmid Wezel 7 2 3 Saw blade Inspect the saw blade at regular intervals If the self locking effect of the hex nut is no longer assured it must be replaced without delay...

Page 16: ...c circular saw blade sharpening machines More detailed information on sharpening the saw blade relating to the different saw blade geometries tooth shapes is available on request from our service depa...

Page 17: ...conditioner defective If necessary replace maintenance unit or return to manufacturer for service Tab 1 Malfunctions and their rectification 8 1 1 Repair by After Sales Service Only specialized person...

Page 18: ...anger of malfunctions and injuries Only authorized specialist personnel may carry out repairs WARNING Cutting hazard Turn off and disconnect the saw from the compressed air supply before starting any...

Page 19: ...Original operating manual Pneumatic circular saws OM No 001 580 654 19 of 19 Version 26 06 2018...

Reviews: