3.2  Conduct at the workplace 

 

Keep your workplace tidy and in good 
working condition. A cluttered or messy 
workplace can lead to accidents. 

 

Take into account environmental 
influences. Ensure good lighting (min. 500 
lux). 

 

Keep other persons away from your 
workplace. Remain focused and act with 
caution during your work.  

 

Do not use the pneumatic circular saw 
when you are tired and/or unfocused. 

 

Avoid wearing loose clothing and jewelry 
that can be caught by moving parts. Wear 
sturdy shoes during your work. Always 
wear a hairnet! 

 

Ensure that your workplace has a correct, 
ergonomic set-up. Ensure safe footing and 
keep your balance at all times. 

 

Store the pneumatic circular saw in a safe 
place. Store unused equipment in a dry 
place.  

 

Service your tools with care. Only use 
sharp and undamaged saw blades to 
ensure safe work. 

 

Use only original EFA accessories. Use of 
other accessories will void the warranty. 
The use of other tool inserts or 
accessories presents a risk of injury to you 
and other persons.  

 

Lay down the unused pneumatic circular 
saw so that accidental contact with the 
sharp saw blade is not possible 

4. Connection and start-up 

4.1  Place of work 

The  work  space  for  the  operator  should  be  at 
least 

1.5 

sqm.  

No other place of  work should extend into  this 
area as movements with the pneumatic circular 
saw could result in the risk of injury.  

The illumination at the place of work must be at 
least 500 lux. 

4.2  Installation 

 

CAUTION 

Danger due to automatic start! 

Connect the pneumatic circular saw 
to  the  power  supply  only  when 
switched off! 

 

 

CAUTION 

Tripping hazard! 

Lay compressed air lines outside of 
the working area. 

 

 

CAUTION 

Danger  of  malfunctions  and 
injuries! 

Installation  work  may  only  be 
carried  out  by  authorized  specialist 
personnel.

 

4.2.1 

Connecting the pneumatic circular 
saw 

The  pneumatic  circular  saw  is  supplied  ready 
for operation. 

 

ATTENTION 

Device damage! 

Operate the pneumatic circular saw 
only with clean, anhydrous, oiled 
air! 

 

 

 

 

Attach the pneumatic circular saw (1) with 
the threaded nipple of the compressed air 

Summary of Contents for 16-8D

Page 1: ...A 17 EFA 19 EFA SK 08D EFA SK 16D EFA SK 16 8D EFA SK 16 8DR EFA SK 18 8D This manual must be given to the user worker A copy of this manual must be given to all personnel working with this tool Schmi...

Page 2: ...splatz 7 4 2 Installation 7 4 2 1 Druckluft Kreiss ge anschlie en 7 4 2 2 Filterdruckminderer 8 4 2 3 Federzug 8 5 Handhabung 9 5 1 Schalterbet tigung 9 5 1 1 Einschalten 9 5 1 2 Ausschalten 10 5 2 Ar...

Page 3: ...ung 15 7 2 1 Werkzeuge und Zubeh r 15 7 2 2 Schmierung 15 7 2 3 S geblatt 15 7 3 Erweiterte Wartung 15 7 3 1 Wartung der S ge 15 7 3 2 Sch rfen des S geblattes 16 7 3 3 Wartungseinheit 16 8 Instandhal...

Page 4: ...WARNING Death severe injury or significant property damage may occur if proper precautions are not taken CAUTION Minor Injury may occur if proper precautions are not taken Mandatory sign Danger to ind...

Page 5: ...effect on the active and passive safety Schmid Wezel GmbH accepts no liability for damage caused using non original spare parts or special designs Modifications and alterations to the machine are not...

Page 6: ...vices disconnected from compressed air supply Read the operating instructions carefully comply with the instructions therein and store them in a place where they are accessible to everyone at all time...

Page 7: ...cessories will void the warranty The use of other tool inserts or accessories presents a risk of injury to you and other persons Lay down the unused pneumatic circular saw so that accidental contact w...

Page 8: ...has accumulated moisture Therefore a filter pressure reducer with water separator should be installed between the compressed air system and the tool This not only controls the operating pressure but c...

Page 9: ...Cutting hazard Limbs may be severed Never reach into the area of the saw blade Wear eye protection or safety goggles during work The pneumatic circular saw is equipped with a valve lever 1 for connect...

Page 10: ...ve application Adjust cutting depth with stop if present loosen wing nut 2 and swivel stop 1 over pivot point 3 Tighten the wing nut 2 see Abb 6 Adjustment range 15 65 mm Adjusting the cutting depth S...

Page 11: ...e needed for disassembly assembly Single open end wrench accessory Retention pin 6 1 1 Removing the depth stop EFA 17 SK16D SK16 8D 1 Loosen the screw 1 at the pivot point 2 Unscrew the wing nut 2 and...

Page 12: ...d to be detached from the saw blade Do not remove the sealing washer 7 with the saw blade 3 EFA SK 08D 1 Insert retaining pin 1 into hole 2 2 Hold drive arm 3 with retaining pin 3 Loosen nut 4 with si...

Page 13: ...asher 2 2 Slide the upper spring washer 3 over the drive arm 4 onto the saw blade 3 Secure the drive arm with the retaining pin 5 and tighten the nut 6 with the single open end wrench 7 6 2 Adjusting...

Page 14: ...ly clean The machine should normally be disinfected before each cleaning Observe the applicable safety and hygiene requirements 7 1 1 Disinfection Disinfect the machine during operation after every cu...

Page 15: ...e from the sales department of Schmid Wezel 7 2 3 Saw blade Inspect the saw blade at regular intervals If the self locking effect of the hex nut is no longer assured it must be replaced without delay...

Page 16: ...c circular saw blade sharpening machines More detailed information on sharpening the saw blade relating to the different saw blade geometries tooth shapes is available on request from our service depa...

Page 17: ...conditioner defective If necessary replace maintenance unit or return to manufacturer for service Tab 1 Malfunctions and their rectification 8 1 1 Repair by After Sales Service Only specialized person...

Page 18: ...anger of malfunctions and injuries Only authorized specialist personnel may carry out repairs WARNING Cutting hazard Turn off and disconnect the saw from the compressed air supply before starting any...

Page 19: ...Original operating manual Pneumatic circular saws OM No 001 580 654 19 of 19 Version 26 06 2018...

Reviews: