Mobile animal stunning device VBE-M
14
The battery charging time from 50 to 100% is approximately 8 hours.
Operation in mains mode:
The device is equipped with a detachable power cord with a plug, which must be connected to the
power system and to the 230 V mains. The cord must not be within reach of animals or be exposed
to damage.
1. Using a detachable power cord, connect the power system to an electrical outlet protected by a
10 A fuse against short circuit and overload;
2. Turn on the power system using the
ON / OFF
switch located on the housing (
Fig. 7 pos. 1
);
3. Turn on the
VBE-M
using the
START
button
(
Fig. 8 pos. 1
) - the device will automatically enter
the
readiness for operation mode
(the device uses mains power);
4.
Fig. 7 pos. 3
- the light indicating the mains supply is on - it means that the
VBE-M
stunning
unit is powered from the mains and not from the power system;
5.
Fig. 7 pos. 4
- the light indicating the battery charging is on:
-
steady red light - battery charging;
-
flashing red-green light - battery charged (recharging in the range of 500-900 mA);
-
steady green light - battery charged.
6.
Fig. 7 pos. 2
- the voltmeter shows the battery charging voltage.
8.2 Starting the device
The device should be turned on in accordance with section
8.1
, depending on the selected
operating mode. The
VBE-M
stunning unit will automatically enter the
boot mode
:
● displays
[A][C]
,
[V]
and
[Prog]
will start blinking for about 2 s indicating the software version
and stunning program number;
● for the next 2 s all displays will show
8
;
● next:
-
displays
[A]
and
[C]
will show
0.0
;
-
display
[V]
will show the measuring voltage.
The device is in
readiness for operation mode
.
8.3 The course of the stunning process
For each of the programs on the device, you can set one of two
stunning modes
:
●
continuous mode
-
head
●
two-stage mode
-
head-heart
The
stunning mode
is determined by the parameters
tP1
,
tP2
and
tP3
- see: section 7.3.
Fig. 7 Power system - mains mode
Fig. 8 VBE-M