Mobile animal stunning device VBE-M
16
Remove the electrodes from the animal’s head
● for
tP=4
or
5
- the red light (STUNNING) will remain turned on - stunning will continue until
the electrodes are removed;
● for
tP=12
or
13
- the red light (STUNNING) will turn off - the stunning will be suspended (the
measuring voltage will appear on the electrodes).
3. After removing the electrodes:
● the yellow light (END OF STUNNING) and the sound alarm will turn off;
● for
tP=4
or
5
the red light (STUNNING) will turn off;
● the device will go into
standby mode
(see:
Diagrams 2
and
3
) - the green light (HEART
STUNNING) will turn on;
The maximum waiting time for reapplying the electrodes to the animal's body is 10 seconds
- after this time, the device will automatically end the stunning process and reapplying the
electrodes will start the next process.
4. To initiate the stunning STAGE II (heart), place one electrode between the animal's eye and
ear, and the other one in the heart area - the stunning process will resume automatically:
The control system will give stunning voltage – the red light (STUNNING) will turn on again:
● display
[A]
will show the stunning current;
● display
[C]
will show the duration [s] counted from the beginning of the stunning process;
● display
[V]
will show the stunning voltage.
5. After reaching the
stunning duration
(
SPt
) or the
sum of phase durations
the yellow light
(END OF STUNNING) and the sound alarm will turn on again - see:
Diagram 2
and
3
.
Remove the electrodes from the animal’s body
After reaching the
stunning duration
(
SPt
), the stunning process continues until the
electrodes are removed from the animal's head or until the
sum of phase durations
is
complete.
The end of the process will be signaled by the red light (STUNNING) turning off.
6. After removing the electrodes:
● the red light (STUNNING) and the yellow light (END OF STUNNING) will turn off;
● the sound alarm will turn off;
● display
[A]
will show
0
(no stunning current);
● display
[C]
will show the duration of last stunning process
● display
[V]
will show the measuring voltage on the electrodes.
7. After reaching the value set in the
toFF
parameter (pause between stunning) the device is in
readiness for operation mode
again.
Whenever the device is not used, turn off the VBE-M stunning unit using the STOP button on
the START / STOP main switch (see: Fig. 3) and the power system using the ON / OFF button
(see: Fig. 5, 7 pos. 1) . If the device is connected to the mains, disconnect it