Mobile animal stunning device VBE-M
18
●
you can similarly change other parameters starting from step 2.
6. Press
to exit the
programming mode
.
10. STUNNING PARAMETER RECORDER
The device is factory-equipped with a recorder which measures electrical parameters and stores
the measured values on an SDHC memory card located in the recorder slot.
The recorder meets the requirements of the Regulation 1099/2009 (Appendix II point 4.1).
10.1 Parameter recording
Parameter recording begins when the stunning process is started - when the red light (STUNNING)
turns on. The stunning parameters are saved as text on the SDHC card, in a
piglog.csv
file.
Each line in the register refers to one stunning process. The values in the row are written in the
following order:
●
subsequent number of the stunning process (it resets after turning the device off);
●
stunning date in
day-month-year
format;
●
the end time of the stunning process in
hour-minutes-seconds
format;
●
average voltage [V] measured during the stunning process;
●
maximum current [A] measured during the stunning process;
●
electric charge [C] measured during the stunning process;
●
duration of the stunning process [s];
●
initial current frequency [Hz];
●
program number;
●
status:
M
- too low stunning current (below the minimum value of 1.3A);
T
- too short stunning time (below the minimum value of 4 s).
Table 7 Sample readings of stunning parameters
CAUTION!
The recorder battery can be replaced only by an authorized service center.
10.2 Parameter reading
To read the recorded data you must:
●
remove the SDHC card from the slot on the device;
●
insert the SDHC card into the SD card reader on your computer;
●
open the
piglog.csv
file in any text file reader (e.g. Notepad) or spreadsheet (e.g. Excel).
Lp.
Date
Time
U[V]
I[A]
q[C]
t[sek]
f[Hz]
NrPgm
Status
1
11.05.2020
12:51:16
162
1.31
6.5
6.8
500
2
----
2
11.05.2020
12:52:11
161
1.32
6.5
6.8
500
2
----
3
11.05.2020
12:53:23
162
0.83
6.5
6.8
500
2
M---
4
11.05.2020
12:54:13
162
1.31
6.5
6.8
500
2
----
5
11.05.2020
12:54:52
162
1.31
6.5
1.2
500
2
--T-
6
11.05.2020
12:55:59
161
1.12
6.5
3.8
500
2
M-T-
7
11.05.2020
12:57:19
162
1.31
6.5
6.8
500
2
----