Registration of stunning parameters on the VBE-M device
If there is an SDHC card in the device, the stunning parameters will be saved:
-
in the registry on the PC
-
in the
piglog.csv
file on the SDHC card
13. CLEANING, MAINTENANCE, REPAIRS AND DISPOSAL
13.1 Cleaning
The device does not require any special maintenance, however, it is necessary to maintain it in
proper technical condition and cleanliness (
Regulation 1099/2009
):
●
clean it manually taking into account the safety rules of using electrical devices;
●
clean the housing after each use by wiping with a cloth;
●
do not use any detergents.
CAUTION!
Do not wash the device with pressure washers.
The device should be protected against moisture and excessive dust.
13.2 Maintenance
The purpose of the maintenance is to keep the device in a state of full technical efficiency. The
scope of maintenance activities should comply with guidelines stated below:
●
Daily maintenance
– before and after operation:
−
consists in constant monitoring of the technical condition of individual assemblies and parts that
impact work safety.
●
Periodic maintenance
:
−
determining the technical condition of the device;
−
determining the degree of wear of individual assemblies and parts of the device;
−
removal of possible faults and damages.
CAUTION!
It is necessary to calibrate the device at an authorized service center once a year (
Regulation
1099/2009
). The service center issues a document confirming that the device has been
calibrated and works properly.
CAUTION!
Stunning devices and tools should be checked before each stunning cycle.
Proper operation of the device can be checked with the
EFA
Tester:
●
connect the Tester to the oblique board socket and turn the device on using the START button;
●
press and hold the button on the Tester to start the simulated stunning process;
●
hold the button until the yellow light (END OF STUNNING) and the sound alarm will turn on;
●
after releasing the button, the simulated stunning process will end: the red light (STUNNING), the
yellow light (END OF STUNNING) and the sound alarm will turn off;
●
the measuring voltage will be displayed on the
display
[V]
.
If the simulated stunning process was successful, the device is working properly.