5
Connection and start-up
5.1
Initial start-up
The breastbone cutter is operated with compressed air
– operating pressure: from 6 to 8 bar.
Before use, check that the operating data of the compressed air supply and the cutter match up.
Caution!
Installation work is only allowed
to be carried out by authorised
specialist personnel.
Switch off the cutter before
connecting to the plant network!
Caution!
Tripping hazard!
We recommend that the lines
are led away upwards.
Lines that run along the floor can
be a tripping hazard for the
operator!
Warning!
When the cutter is not in use,
place it in such a way that there
is no accidental contact with the
sharp blades. This can lead to
injuries.
Warning!
Wear eye protection or protective
goggles and safety shoes when
working!
Connection of the cutter
To connect the cutter, you need the hose unit 001366918.
Remove the sealing plug (1)
see Fig. 5.1
. Then mount the
compressed air plug nipple (2) instead of the sealing plug.
Push the coupling (3) onto the thread nipple until it
engages.
Connect the other end of the hose unit 001366918 to the
compressed air supply, see also
section 5.1.2 Oil mist
lubricator
.
The cutter is now ready for operation.
Fig. 5.1
– Compressed air
connection