19
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - export@effecta.se
▀
Ceramics
1
Grate stick
2
Top left
3
Top right
4
Distribution plate secondary air
5
Bottom left
6
Bottom right
7
Afterburner chamber
8
Widener lower
9
Widener upper
The ceramics tray is installed in the loading compartment. The purpose of the ceramics is to
separate the different combustion zones in the boiler. It is important to monitor the tray since
it is a wear part. In normal conditions, the ceramics tray will last for 6-8 years. When the tray is
used up, combustion and efficiency deteriorate significantly.