Adjustable beam power ring
USER MANUAL EFFI-RING
Version 2.4.2022
Last update:
February 23, 2022
Mini Parc du Verger
–
Bâtiment E
1 Rue de Terre Neuve
91940 LES ULIS, FRANCE
Tel: +33 9 72 38 17 80
Fax: +33 9 72 11 21 69
Email: sales@effilux.fr
UK Importer: Gardasoft Vision Ltd.
Trinity Court, Buckingway Business Park
Swavesey, Cambrige CB24 4UQ UK
Page 3 / 4
CONTACT ARRANGEMENT
The EFFI-Ring is supplied with a 24V constant voltage. The TRIG contact needs to be connected. Max Power consumption = 80W (cable length 2m).
M12 connector
–
Smart control (AutoStrobe)
Contact
arrangement
Number
Color
Contact
Monochrome
version
RGB
version
WUI
version
M12 Male connector
1
Brown
+24V
+24V
+24V
2
White
N/A
Blue TRIG
max 24V
UV TRIG
max 24V
3
Blue
GND
GND
GND
4
Black
TRIG
max 24V
Red TRIG
max 24V
White
TRIG
max 24V
5
Grey
N/A
Green TRIG
max 24V
IR TRIG
max 24V
M8 connector
–
direct control (expert mode)
Contact
arrangement
Number
Color
Contact
Monochromatic
version
RGB
version
WUI
version
M8 Male connector
1
Brown
+V
common
+V
common
+V
common
2
White
GND 1
GND Red
GND White
3
Blue
GND 2
GND Blue
GND UV
4
Black
GND 3
GND Green
GND IR
TRIGGER CONTROL
M12 CONNECTOR
Strobe mode
: Respect a duty
cycle lower than 0.15
CHARACTERISTICS OF THE PULSE
M12 CONNECTOR
CHARACTERISTICS OF THE PULSE
M8 CONNECTOR
Be aware that the maximum current for a given frequency and
a given T
PULSE
cannot be exceeded.
Electronical consideration