SECONDARY CONNECTOR KIT

KD501- KD502 series

Caution!

 

Only personnel qualifying to work with high voltage equipment and circuits are 

allowed to do the installation. 

 

Make sure the circuits are disconnected from the voltage supply and correctly 

grounded. Never connect or disconnect live circuits. Voltage is lethal.

 

Follow the local instructions for safety precautions or refer to the FAA advisory 

circular AC150/5340‐26 (maintenance of Airport visual Aid Facilities). Follow also 

Advisory circular AC150/5370‐10 part XI Lighting installations. Always test the 

installation according to above mentioned documents and local instructions.

 

Make sure that dimensions of the cable comply with the type of connector used. In 

case of any kind of non‐compliance do not proceed with the installation.

 

Check 

www.efla.net

 for possible updates of installation instructions.

Dimensional Data

Plug

Receptacle

Conductor Size

AWG

Cable Diameter

KD501

KD502

1.5‐2.5 mm

2

16‐14

8.5‐13.5 mm

KD501.1

KD502.1

4.0‐6.0 mm

2

12‐10/8

11.5‐18.0 mm

KD501.2

KD502.2

4.0‐6.0 mm

2

12‐10/8

8.5‐13.5 mm