Monitor
EFORT INTELLIGENT EQUIPMENT CO.,LTD
199
Variable
Type
Physical
Address
Unit
Byt
es
Sub-Unit
Remark
System Va
riable
40001
I16
2
BOOL
Bit0: Manual mode
Bit1: Auto mode
Bit2: Remote control
Bit3: Servo status
Bit4: Alarm
Bit5: Emergency stop
Bit6: Program running status
Bit7: Status of safety spot 1.
Bit8: Status of safety spot 2.
Bit9: Status of safety spot 3.
Bit10: Status of safety spot 4.
Bit11: Program loading status
Bit12: Servo preparation status
40002
I16
BOOL
Reserved BOOL type variable
for system,
not available for
users
.
40003
I16
2
I16
Robot operating speed (progra
m oriented)
40004
I16
2
I16
Alarm code 1
40005
I16
2
I16
Alarm code 2
40006
I16
2
I16
Program sequence number indi
cator. (It is used to indicate w
hether a target program is succ
essfully loaded. For example, t
he indicator turns to 2 if the t
arget program whose sequence
number is 2 has been successf
ully loaded to the system, othe
rwise it turns to other value.)
40007~4
0010
I16
I16
Reserved Int type variable for
system,
not available for user
s
.
40011~4
0022
FLOAT
2
*
6
FLOAT
Joint angles for J1 to J6.