Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
244
A.1 System Alarm Code
Alarm Code
Alarm Content
(English)
Alarm Content
(Chinese)
Reasons
Solutions
1
User Registers loss
可保持用户寄存
器值异常
The read value of
user register that can be
kept is inconsistent with
that of the last time when
it was switched off.
If an alarm occurs
when the controller
is powered on,
please keep
pressing the red
ADV button on the
controller and
restart.
2
Parameter Registers
loss
可保持参数寄存
器值异常
The read value of
the parameter register
that can be kept is
inconsistent with that of
the last time when it was
switched off.
If an alarm occurs
when the controller
is powered on,
please keep
pressing the red
ADV button on the
controller and
restart.
3
Alarm History loss
系统报警信息异
常
The system alarm
information is
inconsistent with that of
the last time when it was
switched off.
If an alarm occurs
when the controller
is powered on,
please keep
pressing the red
ADV button on the
controller and
restart.
10
#nn Transducer
Fault (code)
编码器连接异常
Encoder failure
Check the wiring
between the
encoder and the
Robox controller.