254
0x4110
High
ambient
temperature
temperature is too
high.
temperature normal.
1429
0x22000000
Axis %d
0x4210
overheated
of inverter
power
module
1. The ambient
temperature is too
high;
2. The drive is
damaged.
1. Keep the ambient
temperature normal;
2. Repair or replace the
drive.
1430
0x22000000
Axis %d
0x8311
Continuous
overload of
the motor
1. There is a
mechanical jam;
2. The running
time of exceeding
the motor rated
torque is too long.
1. Check the mechanical
transmission part to see
if there is any blocking
phenomenon;
2. Check the load, reduce
the
acceleration
and
deceleration, or replace
the drive and motor with
a larger capacity.
1431
0x22000000
Axis %d
0x6320
Abnormalit
y in
Parameter
data
1. The range of t
he parameter exce
eds the limit;
2. The location un
it is set incorrectl
y.
1. Check whether the
parameter
setting
exceeds the parameter
range that has been set.
2. Check the setting of
the location unit.
1432
0x22000000
Axis %d
0x8611
Excessive
position
following
error
1. The wiring of
the encoder is in
correct, or the con
nector is not conn
ected well.
2. The controller
parameters are
inappropriate;
1. Check the wiring of
the encoder;
2. Re-adjust the control
parameters;
3.
Take
more
anti-interference
measures.