Mechanical Operations and Maintenance Manual for Industrial Robot ER10-1600
27
Chapter Four Overhaul and Maintenance
Overhaul is divided into daily overhaul and regular overhaul. Inspectors must prepare overhaul plans
and carry out overhaul. Please refer to the table below for overhaul items and overhaul periods.
In addition, the overhaul must be carried out every 40,000 hours of work or every 8 years (the
principle of choosing which way to reach the deadline first). The overhaul period is based on the handling
operation. It is recommended to implement maintenance and overhaul in a period of about 1/2 for high
frequency operations such as glaze spraying operations.
In addition, if the inspection and adjustment method is unclear, please contact the company service
department.
4.1 Preventive Maintenance
Follow the method introduced in this chapter and perform regular maintenance steps to maintain the
best performance of the robot.
4.1.1 Daily Inspection
Table 4-1 Daily Inspection Table
Number
Inspection items
Inspection positions
1
abnormal noise
inspection
check whether the transmission mechanism has abnormal noise
2
interference inspection
check whether the transmission mechanism is running smoothly and
whether there is abnormal vibration
3
air cooling inspection
check whether the fan behind the control cabinet is well ventilated
4
pipeline accessories
inspection
check whether it is complete , whether it is worn or not, whether
there is rust
5
peripheral electrical
accessories inspection
check the external wiring of the robot and whether the buttons are
normal
6
leak inspection
check whether there is lubricating oil leakage on the body
4.1.2 Quarterly Inspection
Table 4-2 Quarterly Inspection Table
Number
Inspection items
Inspection positions
1
control unit cable
check whether the teach pendant cable is improperly twisted
2
ventilation unit of control
unit
If the ventilation unit is dirty, cut off the power supply and
clean the ventilation unit
3
cables in the mechanical unit
check whether the socket of the mechanical unit is
damaged, whether it is bent abnormally, and whether the
servo motor connector and the circular connector are
connected reliably
4
cleaning and overhaul of
various components
check whether there is a problem with the component and
deal with it