Mechanical Operation and Maintenance Manual for ER20-1100 Industrial Robot
25
3.2.4 Bracket installation
When the height of the bracket is less than 600mm, its fixing mode is similar to the
ground installation mode, which is divided into two parts: robot base installation, bracket and
ground installation.
When the height of the bracket is more than 600mm, the connection strength between the
bracket and the ground should be strictly checked to ensure that the connection between the
bracket and the ground is safe and reliable.
The specification, quantity and embedded depth of chemical bolt group can be increased
appropriately;
Improve the strength of concrete foundation. The strength of concrete foundation is higher
than that of corresponding chemical bolt.
3.2.5 Upside down installation
When Upside down installation, the fixed bottom plate for the robot base refer to table
3-1 that included in the specifications for ground installation.
In order to ensure safety, the following precautions should be taken during upside down
and wall mounted installation:
1. Install fall protection device, as shown in Figure 3-7 below;
2. Grade 12.9 strength screws shall be used for connection and the tightening torque of
screws shall meet the preload requirements of screws of this specification!
Figure 3-7 Upside down installation
Anti-falling measure