EFORT Intelligent Equipment Co., Ltd
22
socket screws of strength grade 12.9 through the four mounting holes (the length of the screw must ensure
that the screw thread length reaches 1.5 times the nominal diameter of the thread). If there is no loosening
during operation, please fully fix and prevent loosening as shown in Figure 3-6 "Robot Installation
Example".
The first step in ground mounting is to fix the bottom plate to the ground. The thickness of the bottom
plate is recommended to be above 30mm. Use eight M16 or above chemical bolts to fix it. The base of the
robot is firmly fixed on the bottom plate by M16 socket head cap screws of strength level 12.9 through the
four mounting holes (The length of the screw must ensure the screw thread length equals 1.5 times the
nominal diameter of thread). To prevent socket head cap screws loosening during operation, install
2-M12x45 internal threaded dowel pin. Please ensure complete fixing and loosening according to Robot
Installation Diagram as shown in Figure 3-6 below.