25
Environmental
Conditions
Work Conditions
Storing and Transporting Conditions
ambient temperature
0-45℃
-40~55 ℃
relative humidity
40%~90%
(
40℃
)
/
atmospheric pressure
86~106 kPa
vibration
less than 0.5G
,
4.9m/s
2
others
no corrosive gas
Note
:
If strong vibration, dust, cutting oil splashing, or other objects exist in the robot’s working
environment, please contact our service staff and use a cover or equivalents to protect the robot
parts.
3.4 Integrated Application Installation Interface
Table 3-2 Size of External Interfaces
Size of external interfaces
as shown in the figure
Remarks
size of end load installation and
flange
Fig.3-8
size of end load installation
size of external components
installed on upper arm
Fig.3-9
size of external components
size of external components
installed on motor base
Fig.3-10
size of external components
external air pipe and signal line
wiring
Fig.3-11
external air pipe and signal line