Quick Operation Manual for ER3-600 Industrial Robot (EC2-S electric cabinet)
15
Fig.2-6 Robot Installation Demonstration
2.4.4 Supporter Installation
The fixing procedures are the same as those described in ground mounting if the height of the
supporter is less than 600 mm. Install the supporter first and then fix the robot base to the supporter.
The connection strength and reliability between the supporter and the ground needs to be strictly
verified if the height of the supporter is more than 600 mm.
Caution
Increase the size, number and buried depth of chemical bolts for greater stability and
reliability.
Increase the concrete strength to ensure it is greater than that required by the chemical
bolts.
2.4.5 Suspended Installation
The following precautions must be taken to ensure the safety of suspended installation.
1. Install an anti-fall safety device as shown in Fig. 2-7.
2. The strength rate of the connection bolts should be greater than 12.9 and the tightening torque
should match with the pre-tightening force expectations.
Caution
Increase the size, number and buried depth of chemical bolts for greater stability
and reliability.
Increase the concrete strength to ensure it is greater than that required by the
chemical bolts.
Robot base
M20 type of chemical bolts
Concrete floor