Quick Operation Manual for ER3-600 Industrial Robot (EC2-S electric cabinet)
27
3. Click on
Yes to
confirm the
update and
restart the
controller.
The teach pendent cannot
be used before the
controller is fully rebooted.
3.5.2 Remote IO Configuration
Table 3-7 Remote IO Configuration Procedures
Procedures
Demonstration
Remarks
1. Enter the
Remote IO
Configuratio
n page.
Click on “IO setting” on
the teach pendant and
choose “Adapt to remote
IO configuration”.
2. Configure
the remote
IO module.
Type in “1975” in the
password input box and
click on Enter.
Set the module number and
Configure each module.
Select a type from DI, DO,
AI and AO for each
module.
Set the module address.
Note that the length of each
module address varies and
the addresses already
occupied by other modules
cannot be reconfigured.