The channel types as
demonstrated need to be
further defined if the
selected module type is
AM600-4AD or
AM600-4DA.
Click to save the
configuration to file.
Instructions for Remote IO Configuration :
Module Number: Each module within the set number needs to be configured otherwise the
configuration information cannot be successfully saved to file.
Type: There are six module types, namely DI (16-bit), DI (32-bit), DO(16-bit), DO(32-bit) and AI
and AO respectively.
Address: The address ranges from 300-500. The length for each address varies with modules and
the addresses already occupied by other modules cannot be reconfigured.
AM600-0016XXX: 16-bit digital signal output occupying1 I16 register space.
AM600-0032XXX: 32-bit digital signal output occupying 2 I16 register spaces.
AM600-0016END: 16-bit digital signal input occupying 1 I16 register space
AM600-0032END
:
32-bit digital signal input occupying 2 I16 register spaces.
AM600-4AD: analog signal input occupying 4 I16 register spaces.
AM600-4DA: analog signal output occupying 4 I16 register spaces.
Channel: If the selected module is of AD or DA type, the channel type needs to be further defined.
There are 7 channel types of AD modules and 6 of DA modules.
Enable: Tick on “Enable” and load the remote IO configuration changes.
3.5.3 Function IO Configuration
Function IO configuration includes IO input and IO output. Users can define the IO type, IO address
and the valid value and the filter time in the configuration page.
Table 3-8 Function IO Configuration Procedures
Procedures
Demonstration
Remarks