EFORT INTELLIGENT EQUIPMENT CO., LTD
18
3.2.3
Ground installation
The base of the robot is firmly fixed on the bottom plate with M10 hexagon socket screws with
strength class 12.9 (the length of the screw must be 1.5-2 times the nominal diameter of the thread)
through the four mounting holes on it No looseness occurs during the operation of the equipment,
please fully fix and prevent loosening according to the method shown in Figure 3-4 "Robot
Installation Example"
Figure 3-3 Ground installation
Too long or too short screws to fix the robot base will cause bad fixing
accidents!
The connection strength of chemical bolts depends on the strength of concrete.
When the strength of concrete is insufficient, it can be strengthened by the
following methods: increase the number of chemical bolt groups; increase the
embedded depth of chemical bolts