61760V04-2012-09
Seite / Page 22 von / of 28
4.5 Programming – signification of the buttons
For easy programming of the unit proceed according to the following
principle:
Using the main switch at the back of the unit you can enter the standby
mode; either C or F will be displayed.
To leave a function use the button which you used to ”enter“ the re-
spective function. In the majority of the cases the respective display will
flash.
Button T1 (Start)
Pressing this button in the standby mode will start the program run. If
you press this button again after starting the program, the pre-set melt-
ing temperature will be displayed. If you want to change it, change the
value using the button “UP” or “DOWN” (arrow buttons).
The range for adjusting is between 85 °C (185 °F) and 97 °C (206.6 °F).
Then, leave this function by pressing T1 again. A newly entered value
will be permanently adapted (even after the power is turned off). Unless
the point T1 has not been exceeded in the display curve, the new setting will immediately be
adapted into the new program. Factory pre-setting 93 °C (199.4 °F).
Button T2 (standby mode program run)
By pressing this button the pre-set standby temperature is displayed. If you want to change the val-
ue use the button “UP” or “DOWN”. The range for adjusting is between 40 °C (104 °F) and 50 °C (122
°F). Then, leave this function by pressing “T2” again. A newly entered value will be permanently
adapted (even after the power is turned off). A new setting will immediately be adapted into the
new program and the temperature will be readjusted. Factory pre-setting 47 °C (116.6 °F).
Button M (Memory)
The unit is equipped with a memory function. This function counts the melting procedures that
have already been completed, compares the number with a pre-set value and the flashing of the
display reminds you of changing the duplicating material.
Settings for the melting cycles can only be entered in the standby mode, in the program mode only
the number of the melting procedures that have already been completed will be displayed.
Press the button “M”. The number of the melting procedures that have already been completed
will be displayed.
Note: The counter will always be updated when the point T1 is reached.
If you want to erase and reset the counter because you have just changed the material, press the
button “T2” as long as the number of melting procedures is displayed.
Press the ”CLOCK“ symbol to change the given value of the melting procedures. The saved value
will be displayed and can be changed using the button “UP” or “DOWN”. Factory pre-setting “3“.
Leave the memory function by pressing the button “M” again. The values will be saved permanent-
ly.