3.4 Coolant - continued
Coolant replacement
Attention
The coolant line is under pressure;
do not perform any check until the
engine has cooled down and, even if
the engine is cold, the plug of the tank
must be opened with extreme care.
1. Prepare a container having a proper capacity
(about 16 litres).
2. Drain the cooling system by disconnecting
the coolant hose in the bottom of the left side
radiator. (Picture 1)
3. Drain the coolant in the container, then connect
the sleeve.
4. Remove the coolant tank cap and completely
fill the system with coolant. The coolant tank
must be full.
Coolant components
• 50% of ANTIFREEZE.
• 50% of water.
Always use the recommended antifreeze or
equivalent.
5. Put back the radiator cap.
6. Turn on the engine and let it idle for a few
minutes to reach the operating temperature 70-
80°C. If the coolant level alarm appears, top up.
Attention
Hot water.
Coolant tank cap
Coolant hose