www.egiaudio.com
40250, 40260
control unit
38
GAIN ADJUSTMENT (only for
40260
control unit)
EGi
control units are factory calibrated to deliver optimum performance.
Nevertheless, there might be situations, where FM reception is not good enough. In those situations, manual
gain adjustment could sort out the problem.
To perform this operation, do as follows:
1.
Press the
MENU
key
3 times,
AUDIO
>
INTCOM
>
SURVEIL
> until
MISCELL
is displayed.
2.
Press (
OK/+/ON
)
3.
Press the
MENU
key
several times until
ADJSTM
appears.
4.
Press (
OK/+/ON
) for 2 seconds
5.
Press
MENU
key
a few times until
GAIN
appears.
6.
Use (
OK/+/ON
) or (
OFF/–
) to increase or decrease the value between 0 and 3. When
A
appears, the
gain adjustment is set automatically.
intercommunication
COMMUNICATE WITH DIFFERENT ZONES
An added feature of the
DOMOS2
system is the ability to intercommunicate
to any zone of the installation.
1.
Press
MENU
key
a few times until
INTCOM
appears on the display.
2.
Then, press repeatedly (
OK/+/ON
) to see the available zones. If you want
to speak to the whole installation, choose zone
0 (GENERAL)
.
3.
Keep pressed the key
TALK
in the control unit.
TALK
and the zone number
appears on the display.
4.
To return the main menu, press the
EXIT MENU
key
shortly.
GA I N 3
m i s c e l l
GA I N
2
nd
1
st
2
nd
1
st
ta l k 0 0
– I N
T
CO M
2
nd
1
st
Summary of Contents for DOMOS2
Page 1: ...english user s manual ...