40520
interface modules
65
functions
GSM interface module interacts over:
•
Alarms.
•
Intercommunication.
•
Relays.
In two situations:
1.
An alarm goes off (alarm sensor, electrical supply failure, etc.)
2.
The user calls the installation to interact over it.
This module works through menus of pre-recorded messages. To navigate
through the menus, use the keyboard.
ALARM
If any other alarm goes off, the system calls the first telephone number on the
list and sends a pre-recorded message indicating the alarm type.
SMS
In case of electrical supply failure, the system will call the configured telephones
(please see
“
Module Configuration”
). If the electrical supply is restored, the
system will inform the user via SMS.
If the system finds the first configured telephone engaged, it will send a notice
via SMS. In this case, the first telephone would receive the SMS indicating the
alarm type and the system will try to call the following telephone on the list.
Module configuration
On the central unit:
To configure the GSM interface module, a domotic central unit of ref.
40510
or a central unit of ref.
40020,
40040
or
40060
must be installed. On this module, do as follows:
FUNCTION
Access
alarm menu
Access
intercom menu
Access
relay menu
Access main menu
KEY
1
2
3
*
MENU FUNCTION
Deactivate the alarm that has gone off.
Arm intruder alarm.
Disarm intruder alarm.
Go back to the main menu
Talk to the selected zone (one key press
to talk, one key press to listen).
Go back to the main menu.
Activate/deactivate the corresponding relay.
• The GSM module internal relay
corresponds to relay no. 6. The GSM
module general relays correspond to relays
no. 7, 8, 9 and 0.
• Press the corresponding key once to
change the status (open-close or close-
opn). The system has been activated or
deactivated.
KEY
0
1
2
*
0...9
*
6...0
inter
face modules
Summary of Contents for DOMOS2
Page 1: ...english user s manual ...