www.egiaudio.com
40510
auxiliary modules
72
alarms
Your domotic central unit can manage different sensors for detecting fire, gas, flooding or intruders. To
configure it, do as follows:
FIRE ALARM
It allows the fire sensor to determine whether or not generate an alarm. To activate this service, do as follows:
1.
Press the
MENU
key
.
FIRE
will be displayed.
2.
Activate or deactivate the service by pressing
OK/+
(activated) or
NO/–
(deactivated).
3.
When the service is activated, the corresponding indicator triangle is displayed (
1
).
GAS ALARM
It allows the gas sensor to determine whether or not generate an alarm. To activate this service, do as follows:
1.
Press the
MENU
key
.
GAS
will be displayed.
2.
Activate or deactivate the service by pressing
OK/+
(activated) or
NO/–
(deactivated).
3.
When the service is activated, the corresponding indicator triangle is displayed (
2
).
FLOODING ALARM
It allows the flooding sensor to determine whether or not generate an alarm. To activate this service, do as follows:
1.
Press the
MENU
key
.
FLOOD
will be displayed.
2.
Activate or deactivate the service by pressing
OK/+
(activated) or
NO/–
(deactivated).
3.
Cuando el servicio está activado, aparece el triángulo correspondiente en el display
(
3
).
INTRUDER ALARM
It allows to configure the intruder sensors.
1.
Press the
MENU
key
.
INTRUDER
is displayed.
2.
When pressing
(OK/+)
,
T. GO IN
is displayed (available time to deactivate
the alarm system when entering your home).
3.
To modify this parameter (from 1 to 3 minutes), use the (
OK/+
) or (
NO/–
) key.
4.
Press the
MENU
key
now,
T. GO OUT
will be displayed (available
time to deactivate the alarm system when leaving your home).
5.
To modify this parameter (from 1 to 5 minutes), use the
(OK/+)
or
(NO/–)
key.
6.
Press
CANCEL
to go back to the main menu.
I N
T
RU D E R
T
G O I N
: 0 3
T
G O O U T
: 0 2
F I R E
S I
G A S
S I
F L O O D
S I
FIRE
GAS
FLOODING
Intruder alarm activation:
When passing the proximity card over the sensor to activate the alarm,
ALARM ON
is
displayed and the central unit activates the countdown time programmed to leave home.
When this time is finished,
ALARM SET
is displayed on the domotic central unit display.
When the system detects presence,
ALARM ACT
is displayed and the central unit
activates the countdown time programmed to enter home.
If the countdown is over and nobody has passed the proximity card over the sensor,
an acoustic alarm is generated for 2 minutes through the whole installation. After
this time, the acoustic alarm is deactivated but if the intruder alarm has a relay
assigned to it, the relay continues activated until it is manually deactivated.
1
st
2
nd
1
st
2
nd
1
st
2
nd
1
st
2
nd
1
st
2
nd
1
st
2
nd
Summary of Contents for DOMOS2