background image

DOC

EG-IM-GGHC20200313

 

Changzhou EGing Photovoltaic Technology Co., Ltd 
Add

No.18, Jinwu Road, YaotangTown,Jintan District, Changzhou City, Jiangsu, China 

Web

www.egingpv.com

      Email

eging@egingpv.com

      TEL

+86-0519-82588999/82585885 

Date:Mar. 2020                                                                                                                                Page: 

1 / 14 

1.

 

介绍

Introduction

 

☆ 

非常感谢您选择常州亿晶光电科技有限公司的半片双面双玻光伏组件(以下简称

组件

)。

 

Thank you for choosing the Double glass PV modules with bifacial and half-cell of Changzhou EGing 

Photovoltaic Technology Co., Ltd. (Hereinafter referred "modules" ) 

☆  本安装手册提供了亿晶组件的安装和安全使用信息。

 

This manual contains information for the installation and safe handling of EGing modulesPhotovoltaic 

Modules. 

☆  本手册不具备任何质保书的意义。本手册介绍了亿晶组件的安全安装和正确操作

 

☆  的相关信息,在安装、运转和维护组件前,必须仔细阅读本手册。如果有任何问题,请联系我们,以获得

进一步的信息。安装人员必须遵守手册中提到的所有安全防范规则。在安装组件前,安装人员必须熟悉组

件的机械和电气要求。

 

This  manual  does  not  have  the  significance  of  any  warranty  book.  This  manual  introduces  the  safe 

installation  and  handling  information,  please  read  this  manual  carefully  before  installation

transportation  and  maintenance.  If  you  have  any  questions,  please  contact  us  for  further  information. 

The  installation  workers  have  to  observe  all  the  safety  rules  that  this  manual  mentioned.    The 

installation workers must be familiar with the mechanical and electrical requirement of the product.

 

2.

 

免责说明

Disclaimer

 

☆  随着光伏技术的更新,我公司会对说明书相关信息进行改进,恕不另行通知。本说明书只针对陆地安装使

用,用户应该仔细阅读并遵守。请仔细阅读本手册中的描述和图纸,不按照本手册中提到的方法安装组件

会导致保修失效。

 

EGing  reserves  the  right  to  modify  and  update  themanual.  This  specification  installation  manual  only 

meets the ground systems, users should read and observe carefully. Please reading the descriptions and 

drawings in this manual carefully, the guarantee will fail if you do not refer to the installation method in 

this manual.

 

☆  在使用光伏产品时,可能会导致侵犯第三方的专利或其它权利,这些不属于亿晶的责任范围。客户并不因

使用亿晶的产品,而获得任何专利或者专利权利的使用授权,无论是明示的或隐含的。

 

When using modules, you may infringe patents or other rights of third parties, which EGing will not be 

liable  for.  Clients  do  not  have  any  patents  or  the  use  of  patent  rights  authorized  when  using  EGing 

products, expressed or implied.

 

☆  本手册中所有的内容均属于亿晶的知识财产,这些财产源于亿晶长期的技术与经验的探索和积累。

 

The  information  in  this  manual  is  the  intellectual  property  of  EGing,  the  property  is  based  on  EGing 

long-term technology and experience in the exploration and accumulation.

 

3.

 

通则

General

 

☆  组件的安装需要一定程度的专业技能,应该由有合格执照的专业人员进行操作。

 

The  installation  of  PV  modules  requires  a  great  degree  of  skill  and  should  only  be  performed  by  a 

qualified licensed professional, including licensed contractors and licensed electricians.

 

☆  亿晶所有的双玻组件都配备了终端接线盒,接线盒上配有一定长度的线缆和接线头(分公头和母头),方

Summary of Contents for EG-M72-BF-DG Series

Page 1: ...tion 1 2 Disclaimer 1 3 General 1 4 Mechanical Installation 2 4 1 Select the Location 2 4 2 Tilt Angle 3 4 3 Selecting the Proper Support Structure and Hardware 3 4 4 Installing Security 4 4 5 Install...

Page 2: ...rules that this manual mentioned The installation workers must be familiar with the mechanical and electrical requirement of the product 2 Disclaimer EGing reserves the right to modify and update the...

Page 3: ...storage unless you reach the installation site otherwise do not open the package of the modules Follow all safety precautions of other components used in the system 4 Mechanical Installation Regardle...

Page 4: ...rature from 20 to 46 the limit working environment temperature of the module is 40 85 4 2 Tilt Angle The tilt angle of the PV module is the angle between the PV module and a horizontal ground surface...

Page 5: ...ior 4 4 Installing Security Select the appropriate mounting height when modules installation on the ground to prevent the lower half of the modules from being covered by snow for long time in the wint...

Page 6: ...open the box of modules Please protect modules package handle gently when unload modules neverdrop modules directly Do not Stampede modules Do not disassemble modules remove any nameplate or adhered p...

Page 7: ...ndle the cables together with Insulation beam The cables scattering down from the junction box may lead to various problems such as animal bites or leakage in the puddles The cable should not be in pl...

Page 8: ...of the modules Do not block the battery sheet when installing the bracket The distance from the center of the two side blocks to the short side of the modules must be between 306 25mm The distance be...

Page 9: ...inwu Road YaotangTown Jintan District Changzhou City Jiangsu China Web www egingpv com Email eging egingpv com TEL 86 0519 82588999 82585885 Date Mar 2020 Page 8 14 4 Figure 4 Bolted connection betwee...

Page 10: ...ing position of the block is located on the long side of the modules The mounting bracket is parallel to the long side of the modules Do not block the battery sheet when installing the bracket The dis...

Page 11: ...nwu Road YaotangTown Jintan District Changzhou City Jiangsu China Web www egingpv com Email eging egingpv com TEL 86 0519 82588999 82585885 Date Mar 2020 Page 10 14 9 Figure 9 Bolted connection betwee...

Page 12: ...e to the protective diodes 3 4 0 mm2 40 120 This module is supplied withjunction box containing cables and connectors Refer to related standards to determine system wiring size types andtemperature ra...

Page 13: ...g frame the frame surface must be electroplated to ensure a good conductivity The negative pole must also be grounded otherwise the guarantee will fail 5 3 Electrical Safety 1 Contact with electricall...

Page 14: ...ule must be carried out especially during the warranty period It is the responsibility users must bear When the module gets damaged inform the supplier in time usually 2 weeks 5 If the angle of the PV...

Page 15: ...es under STC Type of cells Type of Module Maximum power Pmax W Operating Voltage Vmp V Operating Current Imp A Open Circuit Voltage Voc V Short Circuit Current Isc A Max Series Fuse Rating A system vo...