Lowest temperature values
TH models:
Lowest humidity values
Average temperature values
TH models:
Average humidity values
Querx can save up to 73,728 entries; the WLAN models have
a capacity of 4 million entries. This means that Querx can
store the data of 51 days, when logging one entry per
minute. Querx WLAN can track data for 7.5 years when using
the same settings. Data compression can be activated, in
order to increase the timespan that can be logged. If
compression is activated, entries are only saved if any
change has occurred since the last entry.
The memory is designed as a ring memory. If the memory’s
maximum capacity is reached, the oldest entries will be
overwritten.
1.
Set the interval between logged entries by entering the
required number of minutes in the input field L
ogging
interval
.
2.
If required, activate data
Compression
.
3.
Click
Save
to apply your changes.
⚠
Information
Data compression can lead to noncritical display errors in
the representation of measurements in the diagram.
Basic Configuration
25