7.3 Technical data
Specifications
Measuring range temperature
40 °C to 85 °C
-40 °F to 185 °F
Accuracy
±0.3 °C from -10 °C to 85 °C / ±1.0 °C from -40 °C to -10 °C
±0.5 °F from 14 °F to 185 °F / ±1.8 °F from -40 °F to 14 °F
Resolution temperature
0.1 °C
0.2 °F
Measuring range humidity
0 % bis 95 % RH
Accuracy humidity
±2 % RH from 0 % to 80 % RH at 30 °C (86 °F)
±4,0 % RH from 80 % to 95 % RH at 30 °C (86 °F)
Resolution humidity
1 % RH
Humidity sensor
CMOS IC with polymide film
Calibration
By factory
Sensor heating
Integrated
Ethernet
10/100 Mbit RJ45, HP Auto-MDIX
Operating System
Nut/OS 5
Firmware updates
Via web interface, rescue function
Data capacity
At least 51 days internal
Protocols
DHCP, HTTP, mDNS, Modbus/TCP, SMTP, SNMP, SNTP, Syslog
Web interface
Password protection, diagram, live update, HTML5, CSS3,
JSON and SVG,
User Management (3 Users / 3 Groups)
Up to 4 recipients over 2 SMTP accounts
Status LED
Red, green, yellow
Date / Time
Battery backed real-time clock with SNTP update
Power supply
5 VDC via Micro-USB
Consumption
Typical 120 mA, 0.6W
Maximal 200 mA, 1W
Appendix