1  Safety 

 

 

Throughout this manual, the following symbols will be used to highlight important information and procedures: 

 

Symbol 

Definition 

 

 

WARNING! A dangerous voltage or other condition exists. Use extreme caution when performing these tasks. 

 

CAUTION! This information is critical to the safe installation and or operation of the system.  
Follow these instructions closely. 

 

NOTE: This statement is important. Follow instructions closely. 

 

 

1.1 In case of emergency 

 

In all cases: 
If safe to do so, switch off the AC breakers (external to the system) for the system. 

Contact the fire department or other required emergency response team. 
Evacuate the area, and if applicable, follow your emergency evacuation plan if others are in proximity to the installed location. 
 

In case of fire: 
When safe, use a fire extinguisher suitable for use; including A, B, and C dry chemical fire extinguishers or carbon dioxide 
extinguishers.  Do not use type D extinguishers. 

 
In case of flooding: 

Stay out of water if any part of the system or wiring is submerged. 
Do not attempt to operate batteries that have been submerged in water even after they have been dried. 
 

In case of unusual noise, smell or smoke: 
If safe to do so, ventilate the area. 

 

In case of weather alerts including tornado, hurricane or potentially wind-damaging risk: 
The system is capable of automatically generating emergency backup power on loss of grid, however, in the case where winds are 
potentially threatening to your building structure and safety, it is recommended to shut down your system in advance of, and for the 

duration of, the extreme weather event, and to return to operation only after it appears safe to do so.  
 

 

 

Summary of Contents for Evolve 0513

Page 1: ...Eguana Evolve Model Evolve 0513 DO 68025 Evolve Owner s Manual ...

Page 2: ...hock serious injury or death Operating the product in a way that it was not intended can also result in permanent damage to the product This manual applies to the following products Evolve 0513 Energy Storage System Warranty The Eguana Evolve includes a 10 year standard warranty with performance pro rating for the battery modules Please review the warranty statement included with your product IMPO...

Page 3: ...GENCY 1 1 3 ENVIRONMENTAL PROTECTION 2 2 INTRODUCTION 3 2 1 OVERVIEW 3 2 2 SYSTEM MONITORING ACCOUNT SETUP 4 3 OPERATION 4 3 1 LED DISPLAY INDICATORS 4 3 2 SERVICE BUTTON 5 4 BACKUP POWER OPERATION 5 5 MAINTENANCE 5 6 TROUBLESHOOTING 6 7 INSTALLER CHECKLIST 6 ...

Page 4: ... to the installed location In case of fire When safe use a fire extinguisher suitable for use including A B and C dry chemical fire extinguishers or carbon dioxide extinguishers Do not use type D extinguishers In case of flooding Stay out of water if any part of the system or wiring is submerged Do not attempt to operate batteries that have been submerged in water even after they have been dried I...

Page 5: ...trical panel Ensure proper electrical grounding in accordance with code requirements CAUTION Both AC and DC voltage sources are terminated inside this equipment Each circuit must be disconnected before servicing Risks of Damage The PCS is compatible with the LG Chem battery model EM048126P3S7 only Do not attempt to connect any other battery to the system Do not connect any other loads directly to ...

Page 6: ...ram below shows a typical layout of an AC coupled solar plus storage system Your system may be installed in a manner differently than shown above In addition in accordance with your local electrical code your installer may have included dedicated emergency disconnect switches for your battery and solar systems Consult your system installer regarding the application and installation setup of your s...

Page 7: ...s present operating conditions 3 1 LED Display Indicators The display panel provides indication of the following Battery status state of charge System operating mode out of Service Indicator To conserve energy the LEDs will turn off after 5 minutes from being activated They can be re activated by pressing the service button Indicator Status Display type Color Battery Status State of charge L R 5 L...

Page 8: ...er in the home will be interrupted for up to four seconds before backup power generation commences As a result of this interruption a desktop or portable UPS is recommended if continuous uninterrupted operation is desired for any sensitive electronic equipment In the event that there is not enough solar generation to maintain battery operation in an extended duration grid outage the battery system...

Page 9: ... connection is via wi fi reboot wireless router and make sure login user and password have not been changed since time of original installation Check power to the Evolve energy management system via the orange indicator light on the right side of the panel Note the energy management system may lose power after an extended grid outage where there is not enough solar generation to maintain battery s...