READ THIS FIRST
1.
Install the three AA batteries supplied, by sliding the upper
cover off as shown in figure 3. The green, red & amber
lights will immediately flash in sequence to show they are
working -
this is normal.
Install the Carbon Monoxide Alarm (CO Alarm) in or near
every room that contains a fuel burning appliance, particu-
larly rooms where you spend a lot of time e.g. bedrooms
kitchens, sitting rooms.
Install preferably on the ceiling (300mm from walls) in
rooms with an appliance. Install between 1m to 3m hori-
zontally from appliance. In rooms remote from the appli-
ance install about 1.5 to 2m above floor level at breath
level.
Regularly check that the green power light flashes every
50 seconds. If the unit beeps when the green light flashes
replace the batteries. Important: The CO Alarm will not
work unless there are good batteries correctly installed in
the unit.
Test the unit weekly by pressing the test/hush button. The
horn will sound and the green light will turn on.
4
4
4
4
4
BATTERY POWERED
CARBON MONOXIDE ALARM
Instruction Leaflet
Read and retain carefully for as long as the product is being used. It
contains vital information on the operation and installation. The
leaflet should be regarded as part of the product.
If you are just installing the unit, the leaflet must be given to the
householder. The leaflet is to be given to any subsequent user.
MODEL
Ei
204
MODEL
Ei
205
with Memory
CARBON
MONOXIDE
ALARM
BA
TTE
RY
PO
WE
RE
D
AL
AR
M
FA
ULT
TE
ST
& HUS
H
MO
DE
L:
205
EI
BS
7860
: 1996
(Cont.
Ù
P/N B13584