background image

Amphion User Guide 

 

Page 12 of 26

 

 

Operating the Amphion 

The Amphion is an integral part of the ei

secure network. Amphions 

must be configured with information for the local internet access, 
and the LAN of the equipment with which you want to connect and 
collect data.  The configuration process identifies the following facts 
about the network environment: 

 

The identification of the Amphion device within the ei

secure network, 

 

The method of connection to the Internet, and, 

 

The addresses of the equipment that is protected by the 

Amphion device. 

Amphion Project and Serial Numbers 

The Amphion devices have a 6-digit alphanumeric serial number 
that is unique to each device and does not change.  When 
configured, the Amphion is assigned an ei

3

 Project number which 

should be written or printed on the device label.  This project 
number is used to identify the Amphion within the ei

managed 

secure network for controlling access and connections to your 
equipment. The project number is in the format xxxx-yy where xxxx 
is an alphanumeric string that designates the facility’s Amphion 
network, and yy is a number where -00 is the green box and each 
subsequent number indicates an additional machine. The black box 
uses -01 only.  

  

  

 

The Amphion Serial # and 

ei

3

 Project # are located here

 

Summary of Contents for Amphion S14-H Green Box

Page 1: ...Amphion S14 S14 H green box S14 N red box S14 C black box User Guide ei3 Part Numbers IAA 254 H S14 IAA 30 N S14 IAA 30 C S14 2019 ei3 Corporation Version 2 0...

Page 2: ...8 Optional Wall Plug Power Supply 8 Optional microSD Card 8 Terminations 9 Amphion Wiring and Placement 11 Operating the Amphion 12 Amphion Project and Serial Numbers 12 Configuration 13 1 Configurat...

Page 3: ...S14 This device should only be used with ei3 Corporation approved applications and incorporates technology protected by US Patent 7 054 919 Informations importantes S curit Ces instructions doivent tr...

Page 4: ...lation capabilities to securely connect a machine or integrated line to the ei3 cloud via the Amphion S14 H while isolating them from everything else within the facility and vice versa The S14 N can c...

Page 5: ...Amphion User Guide Page 5 of 26 Figure 1 Amphion Model 14 H and 14 N devices arranged in a typical multiple machine installation configuration...

Page 6: ...awing supplied in the Installation Section of this manual Main Power 24VDC 10W Grounding The Amphion S14 case is grounded and the electronic circuit is isolated Proper installation requires the use of...

Page 7: ...lowed Number of Addresses The Machine LAN port can support up to an entire class C range of IP Addresses 254 addresses Internet S14 H or S14 C Physical Type 10 100 1000 Mbps Ethernet via RJ 45 Autosen...

Page 8: ...VDC power supply a standard wall mounted 24VDC international power supply is available from ei3 This includes the common plugs used in most countries To purchase from ei3 order item IAA PSU X Optional...

Page 9: ...es on this network will be securely accessible To ei3 CAT 5 network cable RJ 45 Network with Internet Access see page 5 for details Connection to the internet for service monitoring 24 Power supply V...

Page 10: ...Amphion User Guide Page 10 of 26 Figure 2 Model S14 face plate...

Page 11: ...of the red box S14 N ensure that the Amphion can be provided an ethernet cable with access to the To Machine interface of the green box For the To Machine port of the green box S14 H ensure that the...

Page 12: ...n device Amphion Project and Serial Numbers The Amphion devices have a 6 digit alphanumeric serial number that is unique to each device and does not change When configured the Amphion is assigned an e...

Page 13: ...iguration using the Web Interface S14 N only This method allows you to input the network information directly into the Amphion device To use this method obtain the username and password for the device...

Page 14: ...t your ei3 administrator to get the file 2 Save the file onto an empty FAT 32 formatted USB drive 3 Power off the Amphion by removing the power terminal 4 Insert the USB drive into the USB slot of the...

Page 15: ...rface 1 Connect your PC to the Amphion S14 using a CAT 5 Ethernet cable to the To Machine port on the device 2 Navigate your web browser to the address provided by your ei3 administrator This can be e...

Page 16: ...The Shop Floor LAN SFLAN is the network that connects the S14 H with the S14 N devices ideally there is no internet access on the SFLAN This page can be used to add the machine device IP addresses to...

Page 17: ...en configured via the USB drive method To change the settings if your Internet access point has a DHCP server available to provide an Internet address then change the DHCP box to YES and you are done...

Page 18: ...the Reboot the Amphion page which shows this Click the Reboot button You will then see a status screen which tells you that the reboot process has begun The process takes up to four minutes and during...

Page 19: ...ure encrypted tunnel has been created through the Internet to ei3 For S14 N one blue Tunnel LED and the System LED will alternately flash to indicate its connection to an S14 H Now the Amphion is oper...

Page 20: ...ates that proper 24VDC power is applied to the Amphion device LED STATUS INDICATES Solid OFF Problem with power Solid ON Correct power supply is applied Green LED System The green System LED indicates...

Page 21: ...S14 H S14 C Amphion has created a secure connection to ei3 S14 N Amphion has a connection to the S14 H Ethernet Link Lights Next to each of the Ethernet ports are two link lights They indicate the fo...

Page 22: ...e Green System LED flashing Amphion is operating normally Green System LED not on Amphion is not running Reboot device by cycling power Amphion may be defective Request RMA Status Indication Probable...

Page 23: ...se Ethernet Link LED not on Either of the two LEDs Network wiring not correct or bad port Check cables and switches Improper configuration of the IP address settings on the Amphion Correct the setting...

Page 24: ...e that there should be a Link Light on the PC 3 Verify that the PC can use this connection to browse to the Internet for secure sites For example type the following into the browser bar https www goog...

Page 25: ...ou believe that your Amphion device is defective or needs repair please follow these steps 1 You must obtain a Return Material Authorization RMA number from ei3 The RMA number is required to authorize...

Page 26: ...and downtime tracking recipe or quality management applications data science services or bespoke solutions to enable the digital transformation of your operations please contact ei3 using the followi...