16
In order to protect the user, the motor and the tool, the
EPO 1310
is
equipped with an electronic and thermal overload protection.
Electronic:
In case of overload caused by a grinding pressure
which is too high, the electronics react by decreasing the
speed of the machine. You can continue working when the
grinding pressure has been reduced.
If you don't relief the pressure on the machine or put
furthermore too much pressure on the tool it reacts by
witching OFF the machine.
After automatic switch-OFF of the machine you can
continue working after switching OFF and ON the power
tool again.
Thermal:
By means of a thermal sensor, in case of continuous
overload, the motor is protected against destruction. In
fact, the machine switches off automatically and only can
be switched on again after a certain cooling period (about 2
minutes). Press the on/off switch. The cooling period
depends on the heating of motor winding and ambient
temperature.
Care and Maintenance
Before the beginning of the maintenance or repair
works you have to disconnect the plug from the
mains.
Repairs may be executed only by appropriately qualified and experienced
personnel.
After every repair the machine has to be inspected by an electric specialist.
Due to its design, the machine needs a minimum of care and maintenance.
However, the following points have to be observed:
Always keep the power tool and the ventilation slots clean.
During work, please pay attention that no particles get inside the
machine.
In case of failure, a repair has to be carried out by an authorised
service workshop.
Environmental Protection