Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 5 bar
Switch-off pressure 8 bar
4. Technical data
Power supply
230 V ~ 50 Hz
Motor rating in kW
1,5
Compressor speed in rpm
2850
Operating pressure in bar
8
Pressure vessel volume in litre
6
Theoretical intake rate in l/min.
206
Sound power level LWA in dB(A)
95,7
Sound pressure level LPA in dB(A)
75,7
Protection type
IP 20
Machine weight in kg
22
5. Possible causes of machine failure
Overloading of the motor and hence triggering of the
overload circuit-breaker may result from:
●
An excessively high mains voltage
●
Excessively high ambient temperatures and an
insufficient air supply
●
Defective compressor valves or a leaking non-
return valve
●
A low level of oil, sluggish connecting rod bearings
Leave a.c. motors enough time to cool off before
switching on again. Avoid touching hot components
and pipe lines.
Ordering replacement parts
Please quote the following data when ordering repla-
cement parts:
●
Type of machine
●
Article number of the machine
●
Identification number of the machine
●
Replacement part number of the part required