thermometer bulb (WB). Outdoor air temperature:
35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device:
20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature:
7°C for dry thermometer bulb (DB), 6°C for wet
thermometer bulb (WB).
Temperature ranges:
Cooling
Room temperature
16°C ~ 30°C
Outdoor temperature
18°C ~ 43°C
Heating
Room temperature
16°C ~ 30°C
Outdoor temperature
0°C ~ 24°C
Dehumidifying
Room temperature
16°C ~ 30°C
Outdoor temperature
18°C ~ 43°C
Notes:
1.
For health reasons the room temperature should
be no more than 5 – 6°C below the outdoor
temperature in cooling mode.
2.
The perfect performance of the system is
achieved within the temperature ranges shown in
the table.
3.
If the air conditioning system is operated below
the temperature range shown above, protection
functions may be activated in certain
circumstances which will cause the device to
operate abnormally.
4.
If the air conditioner is operated in a relative
humidity level of over 80%, condensation may be
deposited on the top of the system which will
then drip on to the floor. In this case set the
horizontal air flap to its maximum angle
(perpendicular to the floor) and set the FAN to
“HIGH”.
4. Intended use
The air conditioner is only designed for cooling,
heating or dehumidifying 2 private homes or
bedrooms.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Description of parts (Fig. 1)
1
LED display
2 Cover
3 Air
filter
4 Slat
5 Wrapping
tape
6 Condensation
hose
7
Infrared remote control
8
Emergency switch for automatic operation
9
Air outlet grille
10 Refrigerant lines
11 Heating function on indicator
12 Cooling function on indicator
13 Temperature display
14 Operation on indicator
15 Dehumidifying function on indicator
16 IR receiver
6. Setting up the remote control (Fig. 2)
Insert batteries
1. Open the battery compartment cover.
2. Insert two new batteries. Be sure to observe the
correct polarity (+/-) of the batteries.
3. Close the battery compartment cover.
Notes
앬
The radio signal has a range of approx. 8 m.
앬
Use two alkali batteries, type R03 AAA (1.5 V).
앬
Always replace both batteries at once when you
can no longer see the LCD display.
앬
Never use a combination of new and used
batteries.
앬
Never use a battery type other than the specified
one.
앬
If the remote control is not used for a lengthy
period of time, remove the batteries to prevent
them leaking.
앬
The service life of the batteries if the remote
control is used normally is approximately 12
months.
앬
Dispose of spent batteries properly.