The following pages are intended for
professional installers.
Important
Do not hesitate to contact our service partners. They
will be able to give you a speedy response to all your
questions so that your system can be installed
correctly.
12. Installation accessories
Before you start to install the devices, please check
that all the installation accessories have been
supplied.
2 mounting plate for the indoor device
2 infrared remote control
4 batteries (type AAA, 1.5 V)
2 condensed water hose (L = 2 m)
2 sealing compound
2 wall hole cap
2 roll of plastic wrapping tape
2 set of refrigerant lines (L = 4 m)
13. Installation instructions (Fig. 9)
Check that the actual mains voltage is the same
as the mains voltage specified on the rating
plate.
앬
Use only suitable fastening material.
앬
Important. Make sure that there are no electric
cables or other installations (for example water
pipes) near the drill holes.
앬
Earth the outdoor device in accordance with
current regulations.
앬
The device must have separate protection
against short-circuits.
앬
Have all work of electrical installation performed
by an electrician.
앬
Ask a service partner or specialist cooling
system firm to undertake all work of installing the
cooling system.
앬
Incorrect installation can lead to injury or damage
to property.
앬
Always wear ear muffs, goggles and work gloves
when performing work of installation.
Notes on electrical connection
Making the electrical connection must be left strictly
to a trained electrician. The system must have
separate protection against short-circuits. Select a
suitably large cable cross-section. The yellow/green
wire is to be used as a protective conductor only and
under no circumstances as a voltage carrying
conductor. The fixed electrical connection of the
device must be capable of being isolated from the
mains power supply by a device with an isolating
distance of at least 3 mm (e.g. circuit-breaker).
Connect the electrical connections of the indoor and
outdoor devices together first and then connect to
the mains power supply. Check first that the entire
system is voltage-free. Secure the system from being
switched on again.
A. Selecting the place of installation
Indoor device
1.
The openings for the inlet and outlet air must
never be covered, otherwise the air will not be
distributed throughout the entire room.
2.
Install the indoor device in a location which
ensures that the distance through the wall to the
outdoor device is as short as possible.
3.
Make sure that the drainage hose does not have
any kinks or upward inclines when you connect it
with the outside.
4.
Do not select a location adjacent to a source of
heat, high humidity or inflammable gas.
5.
Select a location which is firm enough for
installation so that the device is not subjected to
vibrations.
6.
Check that the device has been installed
correctly and exactly.
7.
Make sure that there is sufficient space available
for later repair and service work.
8.
The device should be installed at a distance of at
least 1 m from all other electrical devices and
installations, e.g. TV, radio, computer, etc.
9.
Select a location for the device which is easily
accessible so that the filter can be cleaned or
replaced without difficulty.
10. The maximum distance between the standard
indoor unit and outdoor unit is 4 m. The
maximum possible length of the refrigerant line is
10 m with a maximum height difference of 5 m.
11. Avoid direct sunlight.
Outdoor device
1.
Select a location which avoids causing a
nuisance to neighbours from noise and air
emissions from device.
2.
Select a location which is sufficiently well
ventilated.
3.
Never cover the air inlets and outlets.
4.
The location must be sufficiently firm for
installation and the prevention of vibrations.