GB
- 28 -
11. Troubleshooting
Fault
Possible causes
Remedies
Motor does not start
or comes to a stop
(loose connection)
a) Motor terminals disconnected
b) The mower is standing in high
grass
c) The mower housing is clogged
d) Safety switch is not inserted
e) Battery is not correctly inserted
f) Insu
ffi
cient or no contact between
the handle and the handle fastener
(Fig. 3 / Section 5).
a) Have repaired by the Customer
Service Center
b) Start in low grass or on an area that
has already been mowed; change
the cutting height if necessary
c) Clean the housing so that the blade
moves freely
d) Insert safety switch (see 6.)
e) Remove the battery and reinsert
(see 5.)
f) Undo the handle connection, check
the contacts for dirt and carefully
clean with a brush. Tighten the
handle connection (see 5).
The motor perfor-
mance drops
a) The grass is too high or too damp
b) The mower housing is clogged
c) The blade is severely worn
d) Battery performance decrea-
sing
a) Correct the cutting height
b) Clean the housing
c) Replace the blade
d) Check the battery performance
and charge the battery if necessary
(see 5.)
Cutting is irregular
a) The blade is worn
b) Wrong cutting height
a) Replace or resharpen the blade
b) Correct the cutting height
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period
Anl_Rasarro_SPK13.indb 28
31.08.2021 10:35:51
Summary of Contents for 34.131.80
Page 3: ... 3 3 4 7 13 5 16a 6 16a 8 2 3 4 1 10b 10a Anl_Rasarro_SPK13 indb 3 31 08 2021 10 34 50 ...
Page 4: ... 4 12 13 14 1 15 10 14 11 9 11 11 7 5 12 7 2 Anl_Rasarro_SPK13 indb 4 31 08 2021 10 34 58 ...
Page 5: ... 5 17 15 19 18 16 A B C 18 17 19 1 2 Anl_Rasarro_SPK13 indb 5 31 08 2021 10 35 08 ...
Page 6: ... 6 20 1 2 3 4 5 6 7 8 9 Anl_Rasarro_SPK13 indb 6 31 08 2021 10 35 15 ...
Page 255: ...EH 08 2021 01 Anl_Rasarro_SPK13 indb 255 31 08 2021 10 36 36 ...