GB
- 23 -
hazards may arise in connection with the
equipment’s construction and layout:
1. Damage to hearing if no suitable ear protec-
tion is used.
2. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
Warning!
This equipment generates an electromag-
netic
fi
eld during operation. Under certain
circumstances this
fi
eld may actively or pas-
sively impede medical implants. To reduce
the risk of serious or fatal injuries, we recom-
mend persons with medical implants to con-
sult their doctor and the manufacturer of the
medical implant prior to using the equipment.
5. Before starting the equipment
Important!
The equipment is supplied without batteries and
without a charger is allowed to be used only with
the lithium-ion batteries of the Power X-Change
series!
The lithium-ion batteries of the Power X-Change
series are allowed to be charged only with the
Power-X charger.
Warning!
Always pull out the safety plug before performing
any adjusting, repair, maintenance or cleaning
work on the equipment.
The scari
fi
er is delivered unassembled. The com-
plete push bar must be assembled and mounted
before using the scari
fi
er.
Follow the operating instructions step-by-step
and use the pictures provided as a visual guide to
easily assemble the machine.
Fitting the push bar brackets
(see Figs. 5 and 6)
•
Remove the quick-release lever (Fig. 5/
Item 11) and the washer (Fig. 5/Item 12)
•
Connect the push bar bracket (Fig. 5/Item 5)
to the fastening screw. Make sure that the
curve in the tube (Fig. 6/Item A) is on the out-
side.
•
Now put the washer back on and tighten with
the quick-release lever.
The same tilt angle must be set for both push bar
brackets!
Fitting the lower push bar (see Fig. 7)
•
Slide the lower push bar (Fig. 7/Item 4) onto
the push bar brackets.
•
Now join the tubes together using the screws
(Fig. 7/Item 13), washers (Fig. 7/Item 12) and
quick-release levers (Fig. 7/Item 11) supplied.
Fitting the upper push bar
(see Fig. 8 to Fig. 10)
•
The upper push bar (Fig. 8/Item 3) has two
holes one beneath the other for further height
adjustment of the push bar.
•
Position the upper push bar (Fig. 8 / Item 3)
such that its holes line up with the holes of the
lower bar.
•
Now join the tubes together using the screws
(Fig. 8/Item 13), washers (Fig. 8/Item 12) and
quick-release levers (Fig. 8/Item 11) supplied.
•
Use the cable clips (Fig. 9/Item 10) to attach
the power cable to the tubes of the push bars
so that it is possible to open and shut the
ejector flap (Fig. 10/Item 10).
Please ensure that the ejector
fl
ap can be opened
and closed easily!
Fitting the optional catch basket
(see Figs. 11-14)
•
Push both frame parts into each other (Fig.
11).
•
Pull the grass basket over the metal frame
(Fig. 12).
•
Pull the rubber clips over the metal frame (Fig.
13).
•
To hang the grass basket on the scarifier you
must lift the ejector flap (Fig. 14/Item 9) with
one hand and with the other hand take hold of
the grass bag by the handle and hook it onto
the scarifier from above (Fig. 14).
Danger!
Before you ever hook the grass basket to the sca-
ri
fi
er you must ensure that the motor is switched
o
ff
and the cutting unit is not rotating.
Adjusting the handlebar height (see Fig. 15)
Undo the quick-release levers (Fig. 15/Item 11)
on both sides of the scari
fi
er.
The height of the handlebar can be set to position
1 or 2 (Fig. 15) during operation. You must then
tighten the quick-release fasteners again.
Anl_GE_SA_36_35_Li_SPK13.indb 23
Anl_GE_SA_36_35_Li_SPK13.indb 23
17.02.2022 15:08:57
17.02.2022 15:08:57