GB
- 17 -
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
•
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
•
Operate the equipment only on a firm, level
surface.
Warning!
When using the equipment to in
fl
ate
objects, check the information and safety instruc-
tions provided by the manufacturer.
5.1 Charging the LI battery pack (Fig. 2, 9)
1. Remove the battery pack (6) from the handle,
pressing the pushlock button (a) downwards
to do so.
2. Check that your mains voltage is the same as
that marked on the rating plate of the battery
charger. Insert the power plug of the charger
(d) into the socket outlet. The green LED will
then begin to
fl
ash.
3. Push the battery pack (6) onto the battery
charger (d).
In section 10 (Charger indicator) you will
fi
nd a
table with an explanation of the LED indicator on
the charger.
If the battery pack fails to charge, check for the
following:
•
voltage at the power socket
•
whether there is good contact at the charging
contacts of the charging unit.
If the battery pack still fails to charge, send
•
the charger and charging adapter
•
and the battery pack
to our customer service center.
To ensure that items are properly packaged
and delivered when you send them to us,
please contact our customer service or the
point of sale at which the equipment was
purchased.
When shipping or disposing of batteries and
cordless tools, always ensure that they are
packed individually in plastic bags to prevent
short circuits and
fi
res.
To ensure that the battery pack provides long ser-
vice, you should take care to recharge it promptly.
You must recharge the battery pack when you
notice that the performance of the device drops.
Never allow the battery pack to become fully di-
scharged. This will cause it to develop a defect.
5.2 Battery capacity indicator (Fig. 2)
Press the button for the battery capacity indicator
(b). The battery capacity indicator (c) will indicate
the charge status of the battery by means of 3
LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED blinks:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
6. Operation
6.1 Changing between compressor com-
pressed air operation and blower low-
pressure operation (Fig. 7)
To change over between compressed air operati-
on and low-pressure operation, press the selector
switch (12):
•
Switch to the left: Compressed air operation
•
Switch in the middle: OFF
•
Switch to the right: Low-pressure operation
6.2 Pushbutton „In
fl
ation without pressure
pre-set“ (Fig. 7)
The „In
fl
ation without pressure pre-set” pushbut-
ton (10) can be used to in
fl
ate without
fi
rst setting
the pressure. Press the pushbutton and keep it
pressed in order to start the in
fl
ation operation; re-
lease the pushbutton when the required pressure
is reached.