background image

GB

- 20 -

  Service  information

We have competent service partners in all countries named on the guarantee certi

fi

 cate whose contact 

details can also be found on the guarantee certi

fi

 cate. These partners will help you with all service re-

quests such as repairs, spare and wearing part orders or the purchase of consumables.

Please note that the following parts of this product are subject to normal or natural wear and that the 

following parts are therefore also required for use as consumables.

Category

Example

Wear parts*
Consumables*

Nozzle, 

fl

 uid needle

Missing parts

* Not necessarily included in the scope of delivery!

In the e

 ect of defects or faults, please register the problem on the internet at www.Einhell-Service.com. 

Please ensure that you provide a precise description of the problem and answer the following questions 

in all cases:

• 

Did the equipment work at all or was it defective from the beginning?

• 

Did you notice anything (symptom or defect) prior to the failure?

• 

What malfunction does the equipment have in your opinion (main symptom)?  

Describe this malfunction.

Anl_BT_FSS_500_EX_UK.indb   20

Anl_BT_FSS_500_EX_UK.indb   20

05.10.2021   12:45:34

05.10.2021   12:45:34

Summary of Contents for 42.600.36

Page 1: ...BT FSS 500 Art Nr 42 600 36 I Nr 21011 7 GB Original operating instructions Paint spray system electric Anl_BT_FSS_500_EX_UK indb 1 Anl_BT_FSS_500_EX_UK indb 1 05 10 2021 12 45 24 05 10 2021 12 45 24 ...

Page 2: ... 2 1 2 14 13 13 4 3 15 16 10 9 17 1 2 5 6 7 8 11 8 7 6 10 5 12 18 Anl_BT_FSS_500_EX_UK indb 2 Anl_BT_FSS_500_EX_UK indb 2 05 10 2021 12 45 25 05 10 2021 12 45 25 ...

Page 3: ... 3 3 5 4 5 6 A B C 7 15 13 23 7 5 12 19 20 21 22 23 11 4 19 20 21 22 23 9 Anl_BT_FSS_500_EX_UK indb 3 Anl_BT_FSS_500_EX_UK indb 3 05 10 2021 12 45 26 05 10 2021 12 45 26 ...

Page 4: ... 4 8 50 300mm 9 10 10 9 11 27 26 25 24 8 25 24 11 2 28 29 Anl_BT_FSS_500_EX_UK indb 4 Anl_BT_FSS_500_EX_UK indb 4 05 10 2021 12 45 30 05 10 2021 12 45 30 ...

Page 5: ...ta 5 Before starting the equipment 6 Operation 7 Replacing the power cable 8 Cleaning maintenance and ordering of spare parts 9 Disposal and recycling 10 Storage 11 Viscosity table 12 Troubleshooting guide Anl_BT_FSS_500_EX_UK indb 5 Anl_BT_FSS_500_EX_UK indb 5 05 10 2021 12 45 32 05 10 2021 12 45 32 ...

Page 6: ...sight Caution Wear a breathing mask Dust which is injurious to health can be generated when working on wood and other materials Never use the device to work on any materials containing asbestos Wear gloves Declaration of conformity Products bearing this symbol comply with all applicable Community legislation of the European Economic Area Protection class II double insulated Anl_BT_FSS_500_EX_UK in...

Page 7: ...increa sed if your body is earthed c Keep the tool out of the rain and away from moisture The ingress of water into an electric tool increases the risk of an electric shock d Do not use the cable to carry the electric tool to hang it up or to pull it out of the socket Keep the cable away from heat oil sharp edges and moving parts of the appliance Damaged or entangled cables increase the risk of an...

Page 8: ...ng electric tools for any purpose other than the one for which they are intended can lead to dangerous situations 5 Service a Have your electric tool repaired only by trained personnel using only genuine spare parts This will ensure that your elec tric tool remains safe to use Do not lose these safety instructions Special safety information Always disconnect the mains plug before do ing any work o...

Page 9: ...hes 13 Nozzle set 3 5 mm needle and nozzle 14 Needle removal tool 15 Container for checking the viscosity 16 Cleaning needle 17 Cleaning brush 18 Safety catch 19 Air cap 1 per spraying unit 20 Nozzle 1 per spraying unit 21 Nozzle seal 1 per nozzle 22 Twist cap 1 per spraying unit 23 Needle 1 per spraying unit 24 Venting tube in several pieces 25 Intake tube 26 Lid seal 1 per lid 27 Tub seal 1 per ...

Page 10: ...nitial assessment of exposure Warning The vibration and noise emission levels may vary from the level specified during actual use depen ding on the way in which the power tool is used especially the type of workpiece it is used for Keep the noise emissions and vibrations to a minimum Only use appliances which are in perfect wor king order Service and clean the appliance regularly Adapt your workin...

Page 11: ...filled in Fitting the spraying unit to the motor unit 1 Swing the safety catch 18 on the motor unit 2 down as far as possible see Fig A 2 Insert the required spraying unit 9 or 11 into the motor unit mount such that the line mark on the spraying unit points to the line mark alongside the symbol on the motor unit see Fig B 3 Turn the motor unit clockwise through 90 as far as it will go The line mar...

Page 12: ...es that are difficult to access Spray pattern of the spraying unit for lac quers and varnishes When you turn the adjusting ring take care not to loosen the union nut or unscrew it from the spray ing unit After you have set the required spray pat tern tighten the union nut by screwing clockwise Turn the adjusting ring 12 at the union nut clockwise or counter clockwise in order to move the air cap 19 ...

Page 13: ...engages in the corresponding recess on the side of the nozzle and that the inserted needle is seated in the middle opening of the nozzle 10 Place the air cap onto the spraying unit such that the two side hooks of the air cap lie inside the corresponding recesses on the side of the nozzle 11 Screw the union nut clockwise onto the spray ing unit 6 7 Spraying techniques Important Risk of damage Impro...

Page 14: ...taching replacing the spraying unit 12 Insert the power plug into a properly installed socket outlet 13 Press the trigger 6 and spray the solvent or water into a container or cloth 14 Keep repeating until only clear solvent or wa ter comes out 15 Pull the power plug out of the socket outlet 16 Empty the paint tub completely 17 Keep the tub seal 27 free of material and check it for damage 18 Use a ...

Page 15: ...ndling of the fine paint sprayer could result in damage Never use the fine paint sprayer without an air filter Without an air filter dirt and dust will be drawn in and have an effect on the spraying results Check the air filter at regular intervals for dirt dust and similar Check the air filter particularly if you notice a drop in spraying performance or if you can see that dust is collecting at t...

Page 16: ... your household refuse The equipment should be taken to a suitable collection center for proper dis posal If you do not know the whereabouts of such a collection point you should ask in your local council offices 10 Storage Store the equipment and accessories in a dark and dry place at above freezing temperature The ideal storage temperature is between 5 and 30 C Store the electric tool in its origi...

Page 17: ...preservatives stains oils disinfectants Unthinned max 40 DIN sec 1 0 mm Solvent based or water soluble lacquers primers vehicle topcoats 2 component paints clear lacquers Thin by 0 10 max 40 DIN sec 3 5 mm All other viscous materials Max 150 DIN sec 1 0 mm Anl_BT_FSS_500_EX_UK indb 17 Anl_BT_FSS_500_EX_UK indb 17 05 10 2021 12 45 33 05 10 2021 12 45 33 ...

Page 18: ...re build up in the paint tub is too low Thin the material Turn the setting screw for controlling the ma terial volume to the left Clean the nozzle Clean or replace the air filter Turn the paint tub until tight Intermittent fluttering spray Almost all of the ma terial in the paint tub has been used up Air filter is heavily soiled Fill in more material Clean or replace the air filter Paint runs Too ...

Page 19: ...equipment must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment The old equipment can be returned to a suitable collection point that will dispose of the equipment in accordance with the national recycling and waste disposal regulations This does not apply to any ac cessories or aids without electrical components supplied with the old equipment The r...

Page 20: ...sumables Category Example Wear parts Consumables Nozzle fluid needle Missing parts Not necessarily included in the scope of delivery In the effect of defects or faults please register the problem on the internet at www Einhell Service com Please ensure that you provide a precise description of the problem and answer the following questions in all cases Did the equipment work at all or was it defect...

Page 21: ...nce Damage to the device caused by abuse or incorrect use for example overloading the device or the use or unapproved tools or accessories ingress of foreign bodies into the device such as sand stones or dust transport damage the use of force or damage caused by external forces for ex ample by dropping it Damage to the device or parts of the device caused by normal or natural wear or tear or by no...

Page 22: ...ACIJA O USUGLAŠENOST potvrđuje sledeću usklađenost prema smernicama EZ i normama za artikal TR Uygunluk Deklarasyonu AB direktifi ve ürün standartları uyarınca uygunluğunu beyan ederiz RUS Заявление о соответствии товара Настоящим удостоверяется что следующие продукты соответствуют директивам и нормам ЕС EE Vastavusdeklaratsioon Tõendame toote vastavust EL direktiivile ja standarditele LV Atbilstī...

Page 23: ...d legislation was assessed for Simple Pressure Vessels Safety Regulation X Electromagnetic Compatibility Regulation Electrical Equipment Safety Regulation Measuring Instruments Regulation Radio Equipment Regulation Pressure Equipment Safety Regulation Personal Protective Equipment Regulation The Ecodesign for Energy Related Products and Energy Information Regulation X The Restriction of the Use of...

Page 24: ...EH 10 2021 01 Anl_BT_FSS_500_EX_UK indb 24 Anl_BT_FSS_500_EX_UK indb 24 05 10 2021 12 45 34 05 10 2021 12 45 34 ...

Reviews: