7. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.

8. Cleaning, maintenance and

ordering of spare parts

Important!

Unplug the power plug prior to any maintenance
work.

For mobile applications, the equipment should be
cleaned with clear water after every usage.

For stationary installation, it is recommended that
you check the floating switch for proper
functioning every three months.

Use a water jet to remove any lint or fibrous
particles that may have become trapped in the
housing.

Remove sludge from the shaft bottom and clean
the shaft walls every 3 months.

Use clear water to remove deposits from the
floating switch.

8.1 Cleaning the paddle wheel

If a lot of deposits collect in the housing, the bottom
part of the equipment must be dismantled as follows:
1.  Disconnect the intake cage from the housing.
2.  Clean the paddle wheel with clear water.

Important! 

Do not put down or rest the

equipment on the paddle wheel!

3.  Assemble in reverse order.

8.2 Maintenance

There are no parts inside the equipment which 
require additional maintenance.

8.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:

Type of machine

Article number of the machine

Identification number of the machine

Replacement part number of the part required

For our latest prices and information please go to
www.isc-gmbh.info

9. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.

Anleitung_BG_SP_250_SPK1:_  23.06.2008  11:06 Uhr  Seite 10

Summary of Contents for BG-DP 3530

Page 1: ...mpe submersible C Istruzioni per l uso Pompa sommersa lL Betjeningsvejledning Dykpumpe A Használati utasítás Bemerülő szivattyú Bf Upute za uporabu Podvodna pumpa 4 Uputstva za upotrebu Podvodna pumpa Art Nr 41 702 91 I Nr 01018 BG SP 250 Anleitung_BG_SP_250_SPK1 _ 23 06 2008 11 06 Uhr Seite 1 ...

Page 2: ...rvate le istruzioni per lʼuso e le avvertenze di sicurezza Betjeningsvejledningen og sikkerhedsanvisningerne skal læses inden maskinen tages i brug Alle anvisninger skal følges Üzembehelyezés előtt elolvasni és figyelembe venni a használati utasítást és a biztonsági utasításokat Bf Prije puštanja u rad pročitajte i pridržavajte se ovih uputa za uporabu i sigurnosnih napomena 4 Prije puštanja u pog...

Page 3: ...3 1 4 3 2 1 2 1 1 1 1 2 Anleitung_BG_SP_250_SPK1 _ 23 06 2008 11 06 Uhr Seite 3 ...

Page 4: ... from wet conditions If there is a risk of flooding place the plug in connections in an area which is safe from flooding Strictly avoid pumping aggressive liquids and abrasive substances Protect the equipment from frost Protect the equipment from dry running Take suitable measures to keep the equipment out of the reach of children CAUTION Read all safety regulations and instructions Any errors mad...

Page 5: ...sed comes with an earthing pin plug The equipment is designed for connection to a socket outlet with earthing contact for 230 V 50 Hz Make sure that the socket outlet is sufficiently fused at least 6 A and in good working order Insert the power plug in the socket outlet and the equipment is ready for operation Important To rule out danger this work must be left strictly to a specialist electrician...

Page 6: ... equipment must be dismantled as follows 1 Disconnect the intake cage from the housing 2 Clean the paddle wheel with clear water Important Do not put down or rest the equipment on the paddle wheel 3 Assemble in reverse order 8 2 Maintenance There are no parts inside the equipment which require additional maintenance 8 3 Ordering replacement parts Please quote the following data when ordering repla...

Page 7: ...ufficient pumping rate Intake sieve clogged Performance reduced due to heavily contaminated and abrasive water impurities Clean intake sieve Clean equipment and replace wear parts The equipment switches off after briefly running Motor circuit breaker switches the equipment off due to excessive water contamination Water temperature too high motor circuit breaker switches the equipment off Unplug po...

Page 8: ...arder for produkt j prohlašuje následující shodu podle směrnice EU a norem pro výrobek A a következő konformitást jelenti ki a termékek re vonatkozó EU irányvonalak és normák szerint X pojasnjuje sledečo skladnost po smernici EU in normah za artikel deklaruje zgodność wymienionego poniżej artykułu z następującymi normami na podstawie dyrektywy WE W vydáva nasledujúce prehlásenie o zhode podľa smer...

Page 9: ...native to returning the electrical device the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinquished This can also be done by handing over the used device to a returns center which will dispose of it in accordance with national commercial and industrial waste management legislation This does not apply to the accessories and auxiliary equipment w...

Page 10: ...rug Ikke omfattet heraf er tilbehørsdele og hjælpemidler som ikke indeholder elektroniske komponenter B Samo za zemlje Europske zajednice f Elektroalate ne bacajte u kućno smeće U skladu s europskom odredbom 2002 96 EG o starim električnim i elektroničkim uredjajima i njezinom primjenom u okviru državnog prava istrošeni elektroalati moraju se odvojeno sakupiti i zbrinuti na ekološki način u svrhu ...

Page 11: ... zahtevima za povrat uredjaja Vlasnik elektro uredjaja alternativno je obavezan da umesto povrata robe u slučaju predaje vlasništva učestvuje u stručnom eliminisanju elektro uredjaja Stari uredjaj može da se u tu svrhu prepusti i stanici za preuzimanje rabljenih uredjaja koja će provesti odstranjivanje u smislu državnog zakona o reciklaži i otpadu Zakonom nisu obuhvaćeni delovi pribora ugradjeni u...

Page 12: ...40 Anleitung_BG_SP_250_SPK1 _ 23 06 2008 11 06 Uhr Seite 40 ...

Page 13: ...41 Anleitung_BG_SP_250_SPK1 _ 23 06 2008 11 06 Uhr Seite 41 ...

Page 14: ...serve de modifications Con riserva di apportare modifiche tecniche Der tages forbehold för tekniske ændringer Technikai változások jogát fenntartva Bf Zadržavamo pravo na tehnične izmjene 4 Zadržavamo pravo na tehničke promen Anleitung_BG_SP_250_SPK1 _ 23 06 2008 11 06 Uhr Seite 42 ...

Page 15: ...ʼaccompagnamento dei prodotti è consentita solo con lʼesplicita autorizzazione da parte della ISC GmbH Eftertryk eller anden form for mangfoldiggørelse af skriftligt materiale ledsagepapirer indbefattet som omhandler produkter er kun tilladt efter udtrykkelig tilladelse fra ISC GmbH Az termékek dokumentációjának és kisérô okmányainak az utánnyomása és sokszorosítása kivonatosan is csak az ISC GmbH...

Page 16: ...o the device e g sand stones or dust effects of force or external influences e g damage caused by the device being dropped and normal wear resulting from proper operation of the device The guarantee is rendered null and void if any attempt is made to tamper with the device 3 The guarantee is valid for a period of 2 years starting from the purchase date of the device Guarantee claims should be subm...

Reviews: