8
Points to note when
setting up the
compressor
●
Examine the machine for signs
of transit damage. Report any
damage immediately to the
company which delivered the
compressor.
●
Before you put the compressor
into operation, check the oil
level in the compressor pump.
●
The compressor should be set
up near the working consumer.
●
Avoid long air lines and long
supply lines (extensions).
●
Make sure the intake air is dry
and dust-free.
●
Do not set up the compressor
in damp or wet rooms.
●
The complete compressor has
undergone an official prototype
test. The machine can be put
into operation without further
testing by a technical inspector
(e.g. TÜV). It is important to
keep the supplied factory
certificate and test certificate in
a safe place.
●
The above mentioned
certificates have to be
presented on request to
representatives of your factory
inspectorate. In this connection
see also the manufacturer’s
certificate „Notes for the user“.
Safety instructions for
working with
compressed air and
paint sprayers
Important!
Note the pertinent
accident prevent regulations in
force in your area!
Compressors and lines reach
high temperatures during
operation. Avoid contact! Risk of
burns!
Gases or vapours drawn in by the
compressor have to be kept free
of constituents that may cause
fire or explosions inside the
compressor.
When you disconnect the hose
coupling, hold the coupling
element in your hand to prevent
injury from the whiplashing hose.
Wear goggles when working with
the blow-out gun. Injuries may
easily result from foreign bodies
and blasted parts.
Never point the blow-out gun at
other persons and never use it to
clean clothes that are still being
worn.
Note the safety
instructions for paint
spraying!
Important!
Note the pertinent
accident prevent regulations in
force in your area!
●
Never process paints or
solvents with a flash point
below 21°C.
●
Never heat paints or solvents.
●
It is imperative to use filtering
equipment (face masks) when
processing harmful liquids.
Note also the information
concerning safety precautions
published by the manufacturers
of these liquids.
GB
Read this manual carefully before putting the compressor into operation!
Technical data
EURO 2200-1
Power supply
230 V ~ 50 Hz
Motor rating in kW/h.p.
1,5 / 2
Compressor speed in rpm
2850
Operating pressure in bar
8
Pressure vessel volume in litre
24
Theoretical intake rate in l/min.
210
Sound power level LWA in dB(A)
97
Sound pressure level LPA in dB(A)
87
Machine dimensions in cm
60 x 30 x 64
Machine weight in kg
31
Article No.
40.072.50
Identification No.
01022
The machine is radio-suppressed in accordance with EC Guidelines 82/499 EEC.
The unit is not intended for outdoor operation as per Article 3 of EC Directive 2000/14/EC.