Maintenance: 

Changing of carbon brushes:

Unplug the machine from the power point, loosen screws and remove the service cover. 
Take out the carbon brushes, clean carbon brush holder with compressed air. Insert new 
carbon brushes (those shouldn‘t be jammed in the carbon brush holder), put on pressure 
spring, replace service cover and tighten the screws.

Through the air inlet slots, the sparking can be observed. If heavy sparking occurs the machine has to be 
switched off immediately to prevent any signifi cant damage. It is then advisable to return the machine 
to the dealer for servicing.

Only original carbon brushes should be used. When using generic brushes it will void our war-
ranty obligation. 

Cleaning:

The build-up of metal dust in the interior of the machine should be blown out by compressed air to pre-
vent clogging of the air slots.

 

Transmission:

The bolts on the gear head may not be tampered with during the warranty period, otherwise it would 
void the warranty. The gear grease must be replaced after approximately 1,500 operating hours. This is 
done by loosening the screws, removing the shield and remove the old gear grease cleanly and replace 
by 16 g gear grease.

 

Warranty time:

We provide 12 months warranty (invoice date) on all technical and mechanical parts as long as there is 
no warranty voids. 

Technical Datas 

Mains connection            220 - 240 V  - 50 - 60 Hz
 

(alternative 110V - 50 - 60 Hz 

Rating                               1,750 Watts (1,600 Watts)
Speed                             

infi nitely adjustable from 1,000 to 3,800  

 

rpm, with tacho-generator for constant  

 

speed even under load

Belt dimensions                40 mm x 780 mm
Weight                              4.9 kg

This is how easy it is to replace the 
carbon brushes.Simply unscrew the 
service cover and raise it, replace 
the used carbon brushes, replace 
the cover and secure it. That‘s all 
there is to it! 

EASY, FAST REPLACEMENT OF CARBON BRUSHES 

1

2

3

TIP

Summary of Contents for Pipe-Sniper

Page 1: ...P I P E S N I P E R OPERATING INSTRUCTIONS P I P E T U B E S A N D E R...

Page 2: ...Sniper pipe tube sander guarantees fatique free working with minimum force exertion thanks to the revolutionary sophisticated enclosure technique and the innovative new gas pressure damper system Spee...

Page 3: ...he machine should be blown out by compressed air to pre vent clogging of the air slots Transmission The bolts on the gear head may not be tampered with during the warranty period otherwise it would vo...

Page 4: ...turnrollers can be adjusted to any pipe diameter by simply adjusting the knurled screws 4 Very compact balanced design with bar handle for fatique free working in any position 8 Exclusively from Eisen...

Page 5: ...time PIPE SNIPER towards the pipe Important The maschine runs for safe by using both handles After grinding Important T lever must be released before moving away from pipe Move PIPE SNIPER away from...

Page 6: ...93 84 0 Fax 49 8171 93 84 55 www eisenblaetter de e mail info eisenblaetter de The order basis on the general term of trade EISENBLATTER H i gh Tech S c h l ei f u nd Pol ier t e chnik Order Ordered b...

Page 7: ...TET Vi overtar ansvaret for at dette produktet er i overenstem melse med f lgende standarder eller standard dokumenter EN 60745 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 i samsvar med bestemmels...

Page 8: ...rantee is accepted for a specific property of the product 6 6 shall apply for compensation claims 6 Liability 1 Claims for compensation and for the reimbursement of expenses on the part of the custome...

Reviews: