background image

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C 

08172 Sant Cugat del Vallés · Barcelona (Spain)  

Phone: +34935839543  ·  info@ek.plus  ·   www.ek.plus

 

9

 

 

 

CM 8SH CI-TC 

USER MANUAL

 

 

The main 

“CM Management” 

screen enables easy identification of the different modules connected to 

the power supply, as can be seen in the following screen: 

 

Power supply and head-end manager (red). 

Identification of a module with an input card (green) and an output card (blue). 

Identification of a module with only one input card (green), two  CIs (orange) and 
one output card (blue). 

Identification of a module with two input cards (green) and one output card (blue). 

In  this  case  it  would  be  a  power  supply  and  three  modules,  each  one  with  its 
different internal cards. 

Click on the corresponding module to enter its specific configuration menu. 

Never open the CM MANAGEMENT program twice, this will cause configuration problems. 

 

CM 8SH CI-TC module configuration: 

 
 

 

 
1.

 

Selected module 
 

2.

 

Selected module configuration 
 

3.

 

Input card. Select between 
DVB-S DVB-S2.  
 
NO MULTISTREAM 

 
4.

 

CI section. Activate Watchdog 
 

5.

 

Output card. Select output 
frequency in KHz. 
FLEXIBLE channels and 
different attenuations. 

 
6.

 

Program pool available on the 
configured inputs. 

 

 

 

 

Summary of Contents for 082256

Page 1: ...O B S S L Av Cerdanyola 79 81 Local C 08172 Sant Cugat del Vall s Barcelona Spain Phone 34935839543 info ek plus www ek plus USER MANUAL CM 8SH CI TC 082256 DVB S S2 TO COFDM QAM WITH DUAL CI TRANSMO...

Page 2: ...iption 3 Key features 3 Package contents 3 CONNECTIONS AND INTERFACES 4 INSTALLATION AND WIRING 5 General installation and wiring 5 Installation of a multi module head end 6 CM Management PROGRAMMING...

Page 3: ...with 4 SAT inputs and 8 tuners 1 HDMI input 1 USB 2 0 input Dual CI Common Interface reader Independent control of each i13 18V 22KHz DiSEqC A B C D input Flexible remultiplexing of services on any ou...

Page 4: ...2 HDMI input 3 Status LED Status information of the input tuners 4 Dual CI input 5 Input connectors to each tuner 6 Status LED Reports the status of the COFDM QAM modulated output The output will be...

Page 5: ...r power supply to the next module and output data bus OUT INSTALLATION AND WIRING General installation and wiring 1 For installations of several modules head end or a single module mount the transmodu...

Page 6: ...ese on the same LAN the power supply provided with the address 192 168 0 222 If it is necessary to be connected when not connected to the LAN itself the CM KEY access key must be enabled beforehand 5c...

Page 7: ...power supply It is possible to use the long jumper to deliver the input signal to adjacent modules The attenuation at the output of each module can be adjusted to compensate for cable losses at high f...

Page 8: ...any SW is available the corresponding card will be displayed with a white triangle in the inner left corner By double clicking the button will change the color to orange and the icon will change from...

Page 9: ...two CIs orange and one output card blue Identification of a module with two input cards green and one output card blue In this case it would be a power supply and three modules each one with its diffe...

Page 10: ...mple 11229 MHz 9750 1479MHz S R Symbol Rate of the selected MUX Once the parameters have been correctly configured the signal will be acquired acquired and an approximate value of these parameters wil...

Page 11: ...anges from red to green and this service is assigned to a MUX output DVB T output card This part of the menu consists of three differentiated sections N I T Network Information Table parameters RF out...

Page 12: ...module is changed the power supply must be reset Advanced Configuration LCN Function The transmodulator enables labeling the information Transport Streams so that the TV programs are displayed in ord...

Page 13: ...cted flow will be delivered through the CAM regardless of whether it has to be encoded or not Remote head end management The CM head end can be managed remotely This function is integrated in the FA 5...

Page 14: ...can be installed than for SD channels Why does the head end module not detect anything Set the FA 524 to the left Connect the head end module to the right Plug the power to the FA 524 connect a USB ca...

Page 15: ...No DISEQ Input 1 Standard DVB S2 6 channels in the COFDM modulated program pool 2 Encoded services Channel 21 474000 MHz No attenuation 1 Encoded service Channel 22 482000 MHz No attenuation 1 Uncoded...

Page 16: ...DISEQ B Input 1 Standard DVB S2 16 Encoded channels in the COFDM modulated program pool 4 Channel 25 506000 MHz 10dB attenuation at the output 5 Channel 30 546000 MHz 7dB attenuation at the output 4...