Convection gas oven _ rev. 2__________________________ MODD. EKF 711G UD – EKF 664G UD – EKF 616G UD
_________________________________________________________________________________________ page. 7
1.2 Data-plate and warning-plate
The technical data-plate (Fig.1) and the plate with the installation warnings (Fig. 2) are
permanently and visibly fitted on the rear panel of the oven. An additional plate – to be
removed with all packing material – is situated inside the packing.
eka
Tecnoeka Srl
Via Marco Polo, 11
35010 Borgoricco
Padova (Italy )
2015
0705
N° 705CQ297
IT ; G20 ; 2H ; 20 mbar
Mod.
Serial Number
Qn
Type
: XX
: 13.50 kW
: A1 B11 B21
: EKF 711G UD
G20
G25
G25.1
G2.350
G30
G31
= 1.429 m3/h
= 1.661 m3/h
= 1.658 m3/h
= 1.985 m3/h
= 1.065 kg/h
= 1.049 kg/h
220-230 V AC 50 Hz 500 W
IPX3
100
÷
200 kPa(1.0
÷
2.0 bar)
IT-ES-GB-PT-IE-GR-CH-SK-TR-CZ II2H3+
G20; G30/G31
20; 28-30/37 mbar
DE
II2ELL3B/P G20; G25; G30,G31
20; 20; 50 mbar
LU
I2E
G20
20 mbar
AT-CH
II2H3B/P
G20; G30,G31
20; 50 mbar
BE-FR
II2E+3+
G20/G25; G30/G31
20/25; 28-30/37 mbar
NL
II2L3B/P
G25; G30,G31
25; 28-30 mbar
IS-CY-MT
I3B/P
G30,G31
28-30 mbar
HU
25; 25; 28-30 mbar
PL
II2ELs3B/P G20; G2.350; G30,G31
20; 13; 37 mbar
AL-BA-BG-DK-EE-FI-HR-LT-LV-
II2H3B/P
G20; G30,G31
20; 28-30 mbar
II2HS3B/P
G20; G25.1; G30,G31
LU
I3+
G30/G31
28-30/37 mbar
MK-NO-RO-SE-SI-UA
Fig 1
DE
“Dieses Gerat muß nach geltenden Vorschriften angeschlossen und darf nur in einem gut belufteten Raum betrieben
werden. Bitte beachten Sie vor Inbetriebnahme des Gerates die Gebrauchs- und Wartungsanleitung.“
FR
“L’appareil doit être raccordé conformément aux normes en vigueur et il ne doit être installé que dans locaux bien aérés.
Faire attention aux instructions relatives á l’utilisation et l’entretien de l’appareil avant de le mettre en marche.“
ES
“El apparato debe ser conectado conforme a las normas vigentes y se tiene que instalar solo en locales bien aireados.
Prestese especial atencion a las instrucciones para el luso y mantenimiento del apparato antes de ponerlo en marcha.”
GB
“The appliance must be connected according to the standards in force and must be installed only in well aired premises.
It is recommended to follow the use and servicing instructions of the appliance before operating it.”
PT
O aparelho deve ser ligado em conformidade com as normas vigentes e deve ser instalado somente em locais bem
ventilados. Deve-se prestar particular atenção às instruções para o uso e a manutenção do aparelho antes de pô-lo em
funcionamento.
IT
"L'apparecchio deve essere allacciato conformemente alle norme in vigore e deve essere installato solo in locali ben
aerati.
Si presti particolare attenzione alle istruzioni per l'uso e la manutenzione dell'apparecchio prima di metterlo in funzione."
Fig. 2
GB ; G20 ; 20mbar