3.11.1 Water drain for floor ovens 

The drain pipe is conveyed to an open (grilled) floor drain (Fig.3) and should not go into direct contact with 
the  discharge  point:  the "air  gap" (distance  between  the  drain  pipe  coming  from the appliance  and  the 
open drain) must be at least 25 mm. 
Wall-mounted discharge is also allowed as long as the drain pipe maintains the steady slope of 4-5%. 

 

 

Fig.3 

3.11.2 Water drain for tabletop ovens 

The exhaust pipe can be conveyed to an open (grilled) floor drain (Fig.4); otherwise, between the drain pipe 
of the appliance and the drain point with a "collection cup" (Fig. 5), there must be a height difference of 
at least 30 cm in order to facilitate regular flow of water. In any case, the "air gap" (distance between the 
drain pipe from the appliance and the open drain or the “collection vessel” of the drain duct pipe) must be 
at least 25 mm. 
Wall-mounted discharge is also allowed as long as the drain pipe maintains the steady slope of 4-5%. 

          

 

 

Fig. 4 

Fig. 5 

3.12 Steam drain 

The appliance is equipped with a special metal pipe (DN30) for the discharge of steam from the cooking 
chamber. 
No other type of pipe can be connected to this pipe, which protrudes from the back of the casing. 
Failure to comply with this specific prohibition shall relieve the Manufacturer from any liability concerning 
the potential malfunction of the appliance and poor cooking quality. 
Increasing the length of the original drain hose may result in the formation of abnormal "condensation" in 
the cooking chamber. 
To prevent steam from escaping from the exhaust pipe, place the appliance under the extractor hood, or 
connect it to the "TECNOEKA" extractor hood/condensing hood, specific for the appliance model used. 

Summary of Contents for MKF 1016 S

Page 1: ...ION OF ORIGINAL INSTALLATION AND MAINTENANCE MANUAL SMART OVENS MKF 464 S MKF 416 S MKF 511 S MKF 664 S MKF 664 SP MKF 621 S MKF 616 S MKF 711 S MKF 1064 S MKF 1021 S MKF 1016 S MKF 1111 S MKF 1664 S MKF 2011 S ...

Page 2: ...________________________ 7 3 11 Water drain______________________________________________________________________ 7 3 11 1 Water drain for floor ovens _______________________________________________________ 8 3 11 2 Water drain for tabletop ovens ____________________________________________________ 8 3 12 Steam drain______________________________________________________________________ 8 4 MAINTEN...

Page 3: ...ny ingress of water might affect its safety Before maintenance or cleaning disconnect the appliance from the power supply mains and let it cool In the event of failure or poor operation switch off the appliance close the water supply cock disconnect the power supply and contact an authorised Support Centre Any modification to the electrical system that might be required to install the appliance mu...

Page 4: ...ance with the standards related to facilities and workplace safety in the country of installation The maximum working height referring to the highest surface level must be 1 6 metres from the floor After installing the appliance if required apply the suitable adhesive symbol supplied at a height of 1 6 metres To favour air circulation around the appliance leave a space of about 10 cm between the a...

Page 5: ...ure that the wheels of the tray trolley inserted in the cooking chamber are raised off the floor by not more than 5 mm and that the trolley is supported by the guides at the bottom of the appliance The tray trolley must be moved using the supplied grip The grip must be inserted into place at the front of the trolley up to the stopping point The tray trolley must be inserted inside the cooking cham...

Page 6: ...e gland up to the terminal board Prepare the conductors for the connection with the terminal board so that the earth conductor is the last to be extracted from its terminal should the cable be accidentally pulled The cable connection must be type Y and the insulation of the cable sheath must match type H07RN F The correct section of the cable is shown on the diagram of the power supply terminal bo...

Page 7: ...6 Mod MKF 416 S MKF 464 S MKF 511 S Mod MKF 616 S MKF 664 S MKF 664 SP MKF 711 S Mod MKF 621 S Mod MKF1016 S MKF 1064 S MKF 1111 S Mod MKF 1021 S Mod MKF 1664 S MKF 2011 S ...

Page 8: ...topcock installed in between before connecting the filter drain off a certain amount of water to flush any dirt out of the hose Fig 1 Warning Any damage caused by limescale or other chemicals contained in the water are not covered by warranty 3 11 Water drain Exept for mod MKF 664 SP A drain pipe comes out of the rear of the appliance see the attached Technical Data Sheet to drain the cooking cham...

Page 9: ...from the appliance and the open drain or the collection vessel of the drain duct pipe must be at least 25 mm Wall mounted discharge is also allowed as long as the drain pipe maintains the steady slope of 4 5 Fig 4 Fig 5 3 12 Steam drain The appliance is equipped with a special metal pipe DN30 for the discharge of steam from the cooking chamber No other type of pipe can be connected to this pipe wh...

Page 10: ...board Safety thermostat Capacitors Humidification solenoid valve Magnetic door sensor control transmission relay Cam programmer Motor reversing gear Humidification piping fittings unit Removing the right side Magnetic door sensor door opening to the left Control thermostat bulb door opening to the right 12 way electrical wiring connector for controls on door Removing the control protection box on ...

Page 11: ...sition of the 2 hinges upper and lower of the door and or the cross shaped handle nose projection by doing the following Loss of tightness on the hinges side With the door closed loosen the 6 screws securing the lower hinge 3 screws and upper hinge 3 screws of the door push the door slightly to the side of the hinges so that the inner glass leans on the front gasket hold the door slightly pressed ...

Page 12: ...y contact Tecnoeka on the numbers shown on the cover or refer to the website www tecnoeka com Type of fault Cause of the fault Corrective action Control panel warning lights totally off The oven does not work Non compliant connection to the power mains Check the connection to the mains No mains voltage Restore the power supply voltage Safety thermal device triggered Restore the safety thermal devi...

Page 13: ...hase Including the event in which the customer is unable to produce the invoice receipt or tax receipt as proof of purchase meaning that the terms outlined above are not complied with the warranty is expressly forfeited in the following cases 1 Faults or breakdowns of components caused by transport 2 Damage deriving from inadequate electrical hydraulic and gas supply systems compared to that provi...

Page 14: ...AW AND COMPETENT COURT Supply relationships will be governed by Italian law with the express exclusion of the private international law standards and the Vienna Convention on Contracts for the International Sale of Goods of 11 4 1980 Any dispute will be settled exclusively by the Court of Padua Without prior notice and liability for Tecnoeka Srl the products presented in the manual may be subject ...

Page 15: ...14 ...

Page 16: ...15 REV 0 ...

Reviews: