Technische Informationen / Technical information
TESTS (minimum)
TYPE FFP1
TYPE FFP2
TYPE FFP3
gesamte nach innen gerichtete
Leckage
Total Inward Leakage
<22%
<8%
<2%
Durchlass des Filtermediums
Penetration through the filtering media
<20%
<6%
<1%
Kohlendioxid-Gehalt der Einatemluft
Carbon dioxide content of inhalation air
(%)
<1%
<1%
<1%
Einatem-Widerstand 30 l/min
Inhalation Resistance 30 l/min
<0,6mbar
<0,7mbar
<1mbar
Einatem-Widerstand
95 l/min
Inhalation Resistance 95 l/min
<2,1mbar
<2,4mbar
<3mbar
Ausatem-Widerstand
160 l/min
Exhalation Resistance 160 l/min
<3mbar
<3mbar
<3mbar
Produkte / Range
Best.-Nr. / Part No.
MANDIL FFP1
411 110
MANDIL FFP1/V
411 381
MANDIL FFP2
411 181
MANDIL FFP2/V
411 281
MANDIL FFP2/Soft/V
412 084
MANDIL FFP2/Combi/V
411 250
MANDIL FFP3/V
412 183
MANDIL FFP3/Combi/V
412 888
Piktogramme / Piktogramms
Temperaturbereich der Lagerbedingung /
storage temperature range
Informationsbroschüre des Herstellers beachten /
Consider information supplied by the manufacturer
maximale relative Feuchte der Lagerbedingungen /
XX year
Ende der Lagerfähigkeit
/
Max.shelf life
Maximum storage humidity
NR versus R
NR
the marking NR, i.e. not-reusable, shows that according to the requirement of EN 149, the respirator must not be used for more than a work
shift (max 8 hours) after being exposed to aerosols
R
the marking R, i.e. reusable, shows that according to the requirement of EN 149, the respirator may be used for more than a work shift (max
8 hours) after being exposed to aerosols
CE Kennzeichnung / marking CE 0426
Identifikationsnummer der zertifizierten Prüfstelle, die für die Kontrolle der Produktion zuständig ist: ITALCERT Viale Sarca 336 - 20126 Milano /
with indication of the number identifying the Notified Body who is responsible for the production control: ITALCERT Viale Sarca 336 - 20126 Milano
Manufacturer:
EKASTU Safety GmbH (Group)
Tel.: +49(0)7151 975099-0 Internet: www.ekastu.de
Schaenzle 8 • DE 71332 Waiblingen
Fax: +49(0)7151 975099-30
eMail: info@ekastu.de
Germany
Distributed by:
EKASTU Safety AG
Tel.: +423 380 06 06 Internet: www.ekastu.li
Oberstädtle 8 • FL 9485 Nendeln
Fax: +423 380 06 08
eMail: info@ekastu.li
Principality of Liechtenstein
2002- 2018 by EKASTU Safety GmbH, Waiblingen, Germany Gebr_Mandil 12-08.18